--- title: "01 Access Login and Permissions" slug: "01-access-login-and-permissions" updated: 2026-11-24T20:28:49Z published: 2026-11-24T20:28:49Z canonical: "docs.telosalliance.com/01-access-login-and-permissions" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.telosalliance.com/llms.txt > Use this file to discover all available pages before exploring further. # 01 Access Login and Permissions # Browser Access, Login, and Permissions **Browser-based Remote Control** Almost all of Voltair II’s front-panel functions can be controlled remotely, by logging into its password-protected server from a computer. Voltair II’s Confidence Display, TVC-15 displays and RTA can also be monitored on tablets or smart phones. Voltair II supports three different kinds of access: - **Front Panel Access** uses the unit’s LCD, **jog** wheel, and buttons. It does everything required for normal operation. Full details are in the previous chapter. - Some maintenance functions require a keyboard and hard drive on a connected computer, and don’t appear on the Front Panel. - **Full Web Access** lets you control a remote version of the front panel, using the web browser in any networked computer. It’s password-protected for security, but as with all essential broadcast airchain equipment, it should be behind a firewall. - Normal on-air operating functions, Enhancement and Confidence Analysis settings, and basic system configuration are accessible from the browser. The user interface is almost identical to Voltair II’s front panel, except keyboard and mouse are used instead of the **jog** wheel. - Network-critical functions, such as assigning passwords and IP addresses, must be done from Voltair II’s front panel. This is for security and to prevent accidental disconnection. - Updating Voltair II firmware and downloading Confidence History spreadsheets all require a connected computer. These functions aren’t available at Voltair II’s front panel. - Calibration cannot be started remotely, and must be initiated at Voltair II’s Front Panel. This is to prevent accidental activation. - Some factory support situations may require you to be connected with Full Web Access while you talk to our technical team. - **View-Only Web Access** uses a web browser to mirror the LCD’s Confidence and Real Time Analysis displays. It’s intended for operators and management who want an ongoing view of how well the system is performing. - This access level can be used on many smart phones and tablets, as well as on full computers. - View-Only does not give the user any control over Voltair II. Settings cannot be changed. - View-Only and Full Web Access can have different passwords, both programmed from Voltair II’s front panel. You can restrict Full Access control to engineering and station management, while letting producers and programmers view Voltair and TVC-15 Confidence displays in real-time and over the past hour. - NOTE: The FCC's cybersecurity rule requires broadcasters and Emergency Alert System (EAS) participants to use passwords with a [minimum of 15 characters](https://www.fcc.gov/faqs-EAS-Cybersecurity-Requirements) for critical broadcast equipment starting September 29, 2026. Since Voltair II processes audio in the main airchain, we consider it subject to this requirement, and users in the US should set 15 character passwords to be in compliance. There’s a summary of available functions by access level after the discussion of logging in. **Logging in** The procedure is the same for Full Web and View-Only Access. The only difference is the user name and password, which changes depending on the access level you want. 1. Point your browser to Voltair II’s IP address. This appears on the front panel’s Status screen. If you have multiple Voltair units on your network, each will have a different address. ![image10.png](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image10.png?sv=2026-02-06&spr=https&st=2026-11-26T03%3A43%3A27Z&se=2026-11-26T04%3A43%3A27Z&sr=b&sp=r&sig=ITv1i61zGytwXBWi8mIosrhVMtyqVRXPBDFlNemEncA%3D) The Mask number, which appears after the IP Address, is for system maintenance and not used during log-ins. 1. After your browser contacts Voltair II, it displays an authentication request. ![image47.png](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image47.png?sv=2026-02-06&spr=https&st=2026-11-26T03%3A43%3A27Z&se=2026-11-26T04%3A43%3A27Z&sr=b&sp=r&sig=7i5ITV8xTucWm3DQouiYqaeIqgMXJMvZPNZEXcnFU0o%3D) > > > 1. **If you want to use Full Web Access**, enter voltairweb as the user. Then enter the password you’d assigned for Full Web on the front panel’s System screen. > > > 1. **If you want to use View-Only Access,** enter voltairview as the user. Then enter its password. > > > These user names (voltairweb or voltairview) must be entered as all lower-case, exactly as shown here and on the System screen. > > > Passwords are set by you on the Front Panel System screen. You can use upper- or lower-case, numerals, and some punctuation, but they must be entered exactly as you set them. Passwords can (and probably should) be different for the two access levels. Passwords can be up to 20 characters. After you’ve entered the user name and password, the computer will finish logging in and you can use Voltair II remotely. When you’re finished, you can log out using the button on the upper right corner of your browser’s screen. **Access System Requirements** A single Voltair II will support multiple remote users, in any combination of access levels and functions. You can have Full Web Access running in the operations center and engineering shop, View-Only showing its RTA spectral display to the program producer, and another View-Only showing PPM Confidence graphs or TVC-15 Adaptive Enhancement on the General Manager’s phone. All functions work in real-time, and parameter changes made on one computer or the front panel are reflected on every other screen. You can also have more than one Voltair II running on the same data network. Make sure they have different IP addresses[^44], and access each with their specific IP address. If you’ve assigned your unit a system name (such as Voltair-WTST), from the Setup menu item, it will show up at the top of its remote pages. Full Web and View-Only Access run as dynamic web pages from Voltair II’s internal server. They are standards-compliant, so virtually any modern web browser on any current computer or mobile operating system will work. Functions and Access Levels This table summarizes what you can control or view at each of the three access levels. | | FRONT PANEL | FULL WEB ACCESS | VIEW ONLY ACCESS | | --- | --- | --- | --- | | **Login Name** | *none required* | voltairweb | voltairview | | **Login Password** | *none required* | **Default is "voltair", but can be changed by you, using the front panel** | **Default is "voltair", but can be changed by you, using the front panel** | | **Keyboard/Mouse** | no | required | optional (suitable for smart phones) | | **FUNCTIONS** | | | | | **Main Screen** | Full | Full; adjust parameter by clicking with mouse no | Full | | **Adjust Screen** | Full | | no | | **Pascal Screen** | Full | Full | no | | **TVC-15 Screen** | Full | Full | no | | **System Screen** | Full | Limited: no audio mode or passwords | no | | **Network Screen** | Full | no | no | | **Clock Screen** | Full | Full | no | | **Calibrate Screen** | Full | no | no | | **Status Screen** | Full | Full | no | | **Bypass Mode** | Button | On-screen Button | no | | **ADDITIONAL FUNCTIONS (see below)** | | | | | **Available Tabs** | none | All | Control, History, Information | | **Utilities** | no | Update software; download logs; program audio output switching; factory reset | no | | **History** | no | Download Confidence History spreadsheets | no | | **Information (status summary)** | on separate screens | Full on one page, via tab | | [^44]: If you’re using DHCP , this happens automatically.