# Monitoring and Encoding Enhancement
Benefiting From Voltair II
Monitoring & Analyzing PPM Encoding
It’s vital to know that your watermarking system is working properly. Common wisdom in radio today is, “If you aren’t encoding, you might as well be off the air”.
We would add “decoding” to this equation. PPM is more than Nielsen’s box in your airchain; it’s the complete ecosystem. Technical factors including the encoder, portable meter, acoustic environment, signal processing, and program characteristics all influence what the results will be.
Nielsen’s encoders offer little information about their status, and absolutely no information about the quality of encoding. An encoder’s front panel LED will light green when it’s seen a single code pass through in the last few minutes, and its remote readout can reflect some error conditions.[^5] Nielsen also offers a separate, off-air Encoding Monitor, which can listen to your signal and close a relay if it sees several minutes with no watermarked content.
These failure indicators give you only a coarse “yes/no” reading of basic code transmission. They can’t help you understand and analyze how each subtle difference in your programming can affect encoding reliability. They don’t try to predict what panelists’ meters will be able to detect in the real world.
Failure indicators just aren’t enough for a competitive station that monitors every aspect of its operation, and that needs real tools to measure quality of service.
Voltair II fills that need. It uses multiple methods to measure encoding performance. It presents this information in a convenient dashboard of useful information, gives you a rapid warning if code generation has failed[^6], and allows optional detailed analysis of your encoding history.
Confidence Display
Voltair II gives you confidence you can see. Based on our system models, the Confidence Display constantly updates a picture of your PPM signal’s reliability over the past hour, organized for optimum usability so you can understand the relationship between your programming and watermark performance.

The Confidence Display shows how reliable PPM messages will be in two separate rows: The upper row measures messages being generated by your Encoder. The bottom one shows the Confidence of those same messages, after Voltair applies the Enhancement Level you select.
Quarter-hour Horizontal Blocks
In the US, Nielsen’s PPM credit is awarded on hard quarter hour boundaries. The colored horizontal blocks are summaries of how well your programming carried codes during that quarter hour.
-
A green block means the quarter hour carried sufficient codes to assure reliable ratings.
-
A yellow or red block tells you there might be problems, and that the PPM system might not be able to identify your station for some panelists… which would mean you might not get credit for the audience those panelists represent.
One-minute Vertical Averages
The multiple vertical bars display 1-minute average confidence for every minute in the hour gone by. These are short enough to let you evaluate many individual program elements, such as songs or stopsets[^7].
-
A full height green bar indicates sufficient codes were generated during the minute, so there’ll be very high confidence of successful decoding.
-
A very short red vertical bar tells you there wasn’t enough of the right kind of signal energy during that minute. There weren’t enough reliable codes to properly identify your station.
-
Short red bars may indicate that a minute’s programming didn’t have the right spectral and temporal characteristics to support normal encoding. Or there could have been very low audio levels or dead air.
-
Either way, a short red bar says you should have low confidence that enough codes were generated to get you credit for that minute.
Various heights between these maximum and minimum levels show intermediate confidence values. The resulting graph gives you a detailed map of encoding confidence over time.
Voltair II provides two Energy Meters, as white bars on the extreme right of each graph. They’re more than simple program volume meters. The upper one shows the presence and encoding potential of your audio in the required spectral range. The lower one shows this potential with Voltair enhancement.
The Energy Meters respond quickly to program changes, giving you an immediate sense of encoding possibility. But they can’t incorporate the more deliberate and accurate measurements shown in the confidence graphs, because PPM is a serial data system and complete messages take time to form. Use the Energy Meters as a fast, continuous guide to whether your signal meets the minimum levels for successful encoding.
Decode Interval Display

These two counters show the amount of time, in minutes and seconds, since the last successfully decoded PPM message, both for original (unprocessed) codes, and Voltair II processed codes. Each flashes green and restarts from 00:00 whenever a complete message is successfully decoded from your program stream.
Continuously short timings are good: they mean your programming is carrying a lot of reliable messages. The display will be green.
Longer times between restarts mean your programming isn’t supporting PPM codes well. The display changes to yellow if ten seconds have gone by with no messages; to red if thirty seconds have gone by. While there may be exceptions, chances are your station won’t be identified by the PPM system during those times.
Because the Interval Display is constantly updating, it can provide more detailed information than Voltair’s minute-wide graph bars. This gives you an immediate comparison of the encodability of different types of programming[^8].
Decode Interval is based on a running model of ongoing messages, so it can be a quick guide to message reliability. It doesn’t give you the algorithmic analysis displayed on the one-minute bars and fifteen-minute blocks.
Analyzing Listener Environments
If everyone listened to your station using headphones, the signal would go straight from the receiver into human ears. If they also used an adapter, it could go to a portable meter as well. But most listening is done with speakers, and in a variety of acoustic environments. Whether a listener is driving their car, attending a sports event, or sitting at the dentist’s office, ambient noise is a factor that can affect code reception by portable meters. Watermark detection can be compromised by ambient sounds at panelists’ locations. Noise can interfere with a meter’s ability to recognize your codes, even if the noise isn’t loud enough to stop humans from enjoying your program. In this way, the panelists’ environments can create an unintended technical bias. If nearby noise makes it impossible for their meters to identify your station, this bias could impact the credit due to your station for legitimate listening.
Voltair computes its measurements based on environmental noise levels you specify. This capability lets you build interactive models of how well your programming is encoding against noise in different listening environments.
This way, your enhancement decisions can include whether panelists’ meters are likely to give you credit when they’re in a real, noisy world. Such simulations can give you more insights into the effects of your programming and processing decisions, telling you more than what you’d get with sterile “headphone” listening conditions.
The Voltair and TVC-15 analysis systems are highly effective: they can detect PPM tones in situations where they'd be lost in the real world of random acoustics that actual listeners inhabit. To compensate for this, Voltair II adds an adjustable level of environmental noise to the audio before it is analyzed. The more noise you add, the harder it is for Voltair or TVC-15 analyzers to pick out the PPM signals. (None of this noise goes over the air; it is all internal to Voltair II.)
For each analysis engine, adjust the environment level so that the confidence display is in its middle range: neither all-green nor all-red. This way you can see detailed changes in your signal's confidence
These simulators are available for both the Voltair and TVC-15 analysis engines on the Main Screen. You can set a level between -60 and +10dB, where -60dB is basically “off” and +10dB is a noise level much “hotter” than the actual program signal. Of course, this recorded noise doesn’t get into your air signal. It’s introduced internally for simulation and evaluation, then discarded.

All of Voltair II’s confidence readings are interpreted through the Environment Noise Level you’ve selected to simulate listeners’ current situation.
Importantly, if you are using Adaptive Enhancement to dynamically manage Voltair Processing levels, the TVC-15 Environment level will affect the numbers used to drive enhancement settings. In this case you should adjust the "TCV-15 Env" level to a middle range before you configure Adaptive Enhancement.
Putting It Together
Voltair’s front panel[^9] shows you how well your audio has encoded for the past hour:
-
with your programming,
-
Noise biased to simulate your audience’s typical environment,
-
with and without Voltair II enhancement.
Real-time Spectral Display

RTABoxed.pdf
There is a direct relationship between your program’s spectral energy in a critical range, and whether PPM’s encoder can generate usable codes for your broadcast. While there are other important factors, your signal must provide a good volume between roughly 1 kHz and 3 kHz. Having a lot of energy across this critical range is essential to system reliability.
The real-time spectral display monitors the input to your PPM encoder. It shows program volume levels across the critical region, as a constantly updating display with peak and average readings. It can help you identify problems in your programming, and shows the PPM-relevant effects of some external processing in your signal chain. There’s more about this processing in the Installation section of this manual.
Encoding Enhancement
Voltair II gives you a tool to compensate for real-world listening conditions. To solve this complex technical problem, we had to rely on the disciplines of audio processing, coding technology, ancillary data streams, and content delivery.
The result? Voltair II incorporates an extremely smart and fast adaptive processing engine with finely tuned software, which can continuously detect and enhance the watermarking codes generated by your Nielsen encoder. This improves encoding strength and thus decoding reliability. Voltair helps improve the likelihood of code reception in challenging environments, without altering or otherwise compromising the integrity of your unique watermark signal.
To the human ear, watermark codes are noise. To the “ears” of a portable meter, your programming and any environmental sounds are noise, and codes are the signal. Since humans and meters are listening to the same material, there’s an inherent trade-off between the strength of watermark codes and their audibility to your audience.
Voltair helps you manage this balance between signal and noise. You control the multiple, sophisticated processes of Voltair II’s enhancer with a single knob. You can use Voltair II’s Confidence Display and analysis tools to identify content that doesn’t support optimal encoding performance, and then give it the right level of enhancement for your listeners.
There’s a lot more about choosing appropriate Enhancement levels starting on page 40.
Think of Voltair as an Omnia for your watermark system[^10]. Like the transmitter processor, it makes the signal stronger without changing the actual content. But running too much processing can have an audible effect, and so can running Voltair with too much Enhancement. Of course Voltair processes audio using totally different principles internally: watermarking codes are nothing like normal radio programming, and the intent is to keep them hidden rather than increase their psychoacoustic loudness. But the danger of audibility is similar, and it changes with different kinds of programming and listening situations.
To counter this, Voltair II’s enhancement levels can be adaptively controlled by the integrated TVC-15 watermark analyzer.
Does Voltair II Enhancement really work?
You can test it for yourself.
Voltair II provides ways, using GPIO connections or its own internal test facility, to cycle through different enhancement configurations on a regular basis throughout the day. When you get your station’s ratings report from Nielsen, you can compare these different levels against raw meter counts or AQH listenership. You do this on your own, in the privacy of your own station.
A ratings change might reflect an actual change in audience, rather than issues with code reliability affecting meters. But by doing this test over a period of days, and applying proper controls, you can rule out day-to-day variations. We believe you’ll quickly see a pattern emerge, showing exactly how Voltair II’s processing helps your station get credit for the listeners you have.
[^10]: Or another brand of transmitter processor. The analogy still holds, though Omnia processing includes presets specially designed to work with Voltair.
[^5]: Encoding status is not directly accessible for remote monitoring. However, relay outputs permit remote monitoring when the encoder is in bypass mode and, as a result, not encoding. The encoder will automatically enter bypass mode when it detects a problem, such as a high temperature warning or hardware failure, and warn you of this condition via a separate relay output.
[^6]: You can set how many seconds of code silence are necessary before triggering this alarm, to compensate for programs with long pauses.
[^7]: If you want to evaluate even shorter elements, use our Data Capture and Extraction features. It gives you separate raw confidence readings for both the Encoder output and Voltair’s enhanced codes at 4.8 second intervals—that’s 25 readings per minute—in real-time or for any other broadcast period you specify. These are the basic data Voltair II uses to algorithmically assemble its one-minute and fifteen-minute Confidence Averages. They can’t be used in isolation, but there are techniques for measuring very short elements such as sweepers using an off-line Voltair II.
[^8]: Voltair II’s Data Capture and Extraction features let you see complete reset and confidence information for every 4.8 seconds you’ve been broadcasting. You can select a real-time readout, or specify any past broadcast period. There are also Decode Interval outputs on Voltair II’s back panel: three separate outputs let you know when one minute, two minutes, and five minutes have gone by with no decoded messages; a fourth sends an alarm after a user-specified period of no messages because of dead air or programming that doesn’t support PPM codes.
[^9]: Or remote front panel: You can log into Voltair II’s password-protected web server from any connected computer. You can even show the full Confidence Display on the PD’s desk, while the CE’s computer is showing real-time analysis of the relevant signal spectrum!