# Telnet and Voltair II Control Language
Logging in for real-time and historic data
Voltair II communicates its history via TCP port 8259. If you’re using a Linux or Windows command line or Mac Terminal app, you can start a session with telnet [Voltair IP address] 8259.
You should see this response.
Connected to [Voltair IP address].
Escape character is ‘^]’.
!Welcome to Voltair “Voltair”, firmware 2.3
Then you can issue commands.
Voltair II control language
The language consists of messages sent by the controller (that’s you on your computer) or Voltair II. Each message from the controller results in a single message sent by Voltair II. In addition, Voltair II may asynchronously send messages to indicate specific events. The controller is not expected to respond to these messages.
All messages are composed of lines, each of which is lowASCII characters terminated by an optional <CR>[ASCII 13] and a mandatory <LF>[ASCII 10]. Lines sent by Voltair II end with <CR><LF>. Voltair II treats <LF> as ending a line, and ignores incoming <CR>.
Each message to Voltair II must be a single line. Messages from Voltair II may be single or multiline. Messages are never interleaved; Voltair II will only begin sending a message once the previous message has been completely sent. Each Voltair II message is sent in a single burst, with no significant delays between characters. Messages from the controller can contain arbitrary delays between characters; that is, they can be typed by humans who need to look up language rules while they’re typing.
Voltair II Responses
Voltair II does not echo your commands. If you want to see what you’re typing, you’ll need to use your terminal’s echo function; this is turned on by default if you’re using telnet.
If Voltair II is reporting events, it may continue reporting while you’re giving a command. This may be confusing, but it’s not an error: terminating the controller line will have the desired result.
Voltair II will not respond to a command until <LF> is received.
Responses from Voltair II begin with a result character:
-
!This message is the last line (often the only line) of a response to a successful command -
– This line is part of a multi-line response to a successful command
-
? This message says the last command is unsuccessful or not understood
-
@ This message is asynchronous output, not a response to the immediately preceding command
Voltair II responses end with <CR><LF>.
Permitted Commands
A command is a single line consisting of a command word and an optional argument list, terminated by <CR><LF> or just <LF>.
Commands and individual arguments are separated by spaces, and the language is case-sensitive.
If there is an error in a message, Voltair II responds with
? [error message] <CR><LF>.A line feed by itself, or a line that consists of just <CR><LF>, will result in
!An empty command (just a <LF> or <CRLF>) will result in a “!”
| Command | Description | Voltair II response |
|---|---|---|
| Enable | Enables live, asynchronous reporting of [argument] data. The only currently supported argument is all, which enables full reporting subject to licensing. |
!enable all Voltair II starts reporting data once per second |
| Disable | Disables asynchronous reporting of the specified data. The only argument in current software is all. |
!disable all ”. |
| Get | Gets the current value of the specified data. If desired, more than one argument can be specified in a single command. Argument: replayCatalog |
get replayCatalog= YYYYMMDD,YYYYMMDD,... where the dates are those available which have saved data |
Argument: rights |
!get rights= XXXX, where “XXXX” is none , standardData or enhancedData |
|
| Replay | Display all the data for a specified date. Dates must be in the format of, and listed by, a replayCatalog. You can add a two-digit hour (in 24-hour format) after the date, and Voltair II will limit the response to that hour. | Voltair II immediately responds with a series of lines describing the date and time being reported, the identification of each reported state, and its value. Each line begins with –, except the final line begins with! |
| help | If no arguments, then lists all valid commands. | !commands are: enable disable get replay help; for more info type “help” and the command |
If a single command is given as an argument, gives detailed help on that command. (example help replay) |
(example) !replay: play back data on given date (argument in YYYY-MM-DD format) |
Data appears as a series of lines describing the operating parameters and output mode, and time-stamped confidence values every second.
| Keyword | Description | Example |
|---|---|---|
| confidence1Minute=<raw>,<enh> | Per-minute Voltair confidence before/after enhancement, scaled to 0-1 | confidence1Minute=1,1 |
| confidence15Minute=<raw>,<enh> | Per-15-minute Voltair confidence before/after enhancement, scaled to 0-1 | confidence15Minute=1,1 |
| confidenceNow=<raw>,<enh> | Per-message Voltair confidence before/after enhancement, scaled to 0-1 | confidenceNow=1,1 |
| date=YYYY-MM-DD | The current or replayed date | date=2026-09-23 |
| decodeIntervalOriginalReset | The original interval has reset | decodeIntervalOriginalReset |
| decodeIntervalProcessedReset | The processed interval has reset | decodeIntervalProcessedReset |
| enhancementLevel=<value> | Current Voltair enhancement level | enhancementLevel=8 |
| environmentLevel=<value> | Current Voltair environment level | environmentLevel=-30 |
| notEncoding=<value> | Shows whether Voltair detects that the PPM encoder is encoding | notEncoding=1 |
| pascalConfig=<enabled>,<threshold>,<level>,<inGain> | Pascal configuration | pascalConfig=1,17,6,21 |
| preset=<value> | Current preset. 0 if none. | preset=2 |
| running=<value> | Shows whether Voltair is running | running=1 |
| time=<time> | Current time, in HH:MM:SSZZZ format | time=15:25:40EDT |
| tvcConfig=<envGain>,<enabled>,<delay>,<confMin>,<confMax>,<enhMin>,<enhMax> | TVC configuration | tvcConfig=-56,0,2,0.2,0.8,2,20 |
| tvcMessage=<id>,<hours>:<minutes>,<confidence> | TVC detected a PPM message, with encoder ID, timestamp in HH:MM format (local time), and confidence (range 0 to 1) | tvcMessage=7d2f5a,16:32,0.32 |