--- title: "Control Room Monitor volume does not adjust" slug: "control-room-monitor-volume-does-not-adjust" updated: 2024-12-13T10:31:39Z published: 2024-12-13T10:31:39Z canonical: "docs.telosalliance.com/control-room-monitor-volume-does-not-adjust" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.telosalliance.com/llms.txt > Use this file to discover all available pages before exploring further. # Control Room Monitor volume does not adjust ## Scope This document applies to both Fusion and Element consoles and covers cases where the Control Room Monitor volume can not be changed. ## Description There is generally one of three things that will prevent the Control Room Monitor Volume from being adjusted. - Wrong Livewire source routed to the speakers - The Show Profile locks the Control Room Monitor volume - The rotary encoder (volume knob) is bad ## Routing the correct Source to the monitors Make sure that the CR Monitor channel is correct in the node that feeds your speakers. In our example here, the CR Monitor channel is 6011. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/b6d029f5-e262-44fd-9594-ab39119f6e82-image.png?sv=2026-02-06&spr=https&st=2026-11-07T18%3A12%3A59Z&se=2026-11-07T19%3A12%3A59Z&sr=c&sp=r&sig=4LCP97H1tvWgOB9hJJQLOUyW3MLSuc6l6DHC9TKaroY%3D) > [!WARNING] > Do not confuse the CR Monitor with Studio Monitor. CR Monitor is the room where the physical Fusion or Element console resides. The Studio is a separate room from the Control Room with a different monitor output. The Control Room Monitor (also called Monitor 1) volume knob controls the CR Monitor output. The position of the knob on the screen will change when turning the console volume knob. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/af2249ae-fb87-44a9-b9e6-b175026f4c24-image.png?sv=2026-02-06&spr=https&st=2026-11-07T18%3A12%3A59Z&se=2026-11-07T19%3A12%3A59Z&sr=c&sp=r&sig=4LCP97H1tvWgOB9hJJQLOUyW3MLSuc6l6DHC9TKaroY%3D) ## Locking the CR Monitor volume The Show Profile can lock the CR Monitor volume. 1. In the Web UI of your console, select **Shows** under the **Console** heading. 2. Select the desired **Show** from the **Profiles List**. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/e5715e86-7831-4ce6-a46a-16dc24ee7763-image.png?sv=2026-02-06&spr=https&st=2026-11-07T18%3A12%3A59Z&se=2026-11-07T19%3A12%3A59Z&sr=c&sp=r&sig=4LCP97H1tvWgOB9hJJQLOUyW3MLSuc6l6DHC9TKaroY%3D) 3. Select the **Monitor** section of your Show Profile and scroll to the bottom to the **Master module control lock map** section. 4. Under the **Volume Controls** heading, make sure the **CR Monitor** box is NOT checked. > [!NOTE] > Changes to any profiles require reloading of that profile to effect the change. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/d77be782-1472-4b3c-9076-58181bff45aa-image.png?sv=2026-02-06&spr=https&st=2026-11-07T18%3A12%3A59Z&se=2026-11-07T19%3A12%3A59Z&sr=c&sp=r&sig=4LCP97H1tvWgOB9hJJQLOUyW3MLSuc6l6DHC9TKaroY%3D) > [!WARNING] > Checking the box LOCKS the user operation of those controls. Locked controls can only be controlled by Show Profile or by remote control by some external program like an automation system or by Pathfinder. ## Checking for a defective rotary encoder The simplest way to check the physical operation of the knob is to look at its numerical value on the Modules page. 1. Navigate to the **Modules** page in the web UI of your console 2. Locate the Master module, as shown here. > [!WARNING] > Yours may differ slightly; however, there is only one Master module in a system. Modules are labeled with their Type 3. Rotate the knob and refresh the page, then look for a value to change. In our example, RE02 (Rotary Encoder 02) reports a different value each time it's turned, and the page is refreshed. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/2c07c522-3f7d-4ddd-a20e-2013aa5f26ee-image.png?sv=2026-02-06&spr=https&st=2026-11-07T18%3A12%3A59Z&se=2026-11-07T19%3A12%3A59Z&sr=c&sp=r&sig=4LCP97H1tvWgOB9hJJQLOUyW3MLSuc6l6DHC9TKaroY%3D) > [!WARNING] > The page does not refresh in real-time; you must refresh it manually. If the value changes, there is no problem with the rotary encoder. If the value does not change, you can remove the module from the console and SWAP the CR Monitor and Headphone knobs. They are the same. Swap the two cables from their original positions, as shown here. The wires are long enough to reach both locations. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/2bca17c4-ded6-4f5b-91da-71d48426bf06-image.png?sv=2026-02-06&spr=https&st=2026-11-07T18%3A12%3A59Z&se=2026-11-07T19%3A12%3A59Z&sr=c&sp=r&sig=4LCP97H1tvWgOB9hJJQLOUyW3MLSuc6l6DHC9TKaroY%3D) If you find that the rotary encoder is defective, you can request Telos part number 1771-00022-100. The rotary encoder can be replaced in the field by [following these instructions](/v1/docs/replacing-a-monitor-or-headphone-rotary-encoder-on-fusion-or-element). If your unit is under warranty, we will ship one to you free of charge. ## Let us know how we can help If you have further questions on this topic or have ideas about how we can improve this document, please [contact us](https://www.telosalliance.com/support-request).