--- title: "Safeguards" slug: "v22-safeguards" updated: 2024-11-14T07:16:53Z published: 2024-11-14T07:16:53Z canonical: "docs.telosalliance.com/v22-safeguards" deprecated: true --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.telosalliance.com/llms.txt > Use this file to discover all available pages before exploring further. # Safeguards > **Deprecated.** This document is obsolete and is retained for reference purposes only. For current and supported documentation, please refer to the T[elos Infinity documentation home page.](https://docs.telosalliance.com/docs/telos-infinity) Dashboard allows manual logical devices to be created on the Livewire+™ AES67 network. For example, an IFB or Auxiliary audio feed may need to be manually created within Dashboard and as part of the configuration, a multicast/channel number must be assigned. During this configuration, Dashboard will check to see if the number is outside the allocated range for Infinity, if it is, a warning message appears seeking clarification that this is really required. If a destination channel number or AES67 multicast/channel number is manually changed on a device such as an xNode, and this was already allocated to a Dashboard instance (such as a Group, Partyline, IFP, virtual panel etc), then Dashboard will automatically disconnect the stream. This is to inhibit the effects of duplication of multicast/channel numbers on other Livewire+™ AES67 devices and stop the intercom feeds from appearing on the output of other devices. ![Figure 1 - Multicast or channel number safeguard](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/picture129(3).png) Figure 1 - Multicast or channel number safeguard