--- title: "xNode2 sources not displayed properly in iProbe" slug: "xnode2-sources-not-displayed-properly-in-iprobe" updated: 2025-09-03T20:44:06Z published: 2025-09-03T20:44:06Z canonical: "docs.telosalliance.com/xnode2-sources-not-displayed-properly-in-iprobe" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.telosalliance.com/llms.txt > Use this file to discover all available pages before exploring further. # xNode2 sources not displayed properly in iProbe ## Scope This document covers an issue that may cause xNode2 sources to display incorrectly in iProbe. This is specific to xNode2 and iProbe. No other topics are covered here. ## Description Sources from an xNode2 may display incorrectly in iProbe and look like this. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image-FULS14SY.png?sv=2026-02-06&spr=https&st=2026-11-01T19%3A28%3A45Z&se=2026-11-01T20%3A28%3A45Z&sr=c&sp=r&sig=U1rvE5cte%2F1zuAqi9nbubuXyN%2B8tf2jbCGPVBJvkXSY%3D) > [!WARNING] > Note that the first source (11401 AV Mix) is correct, but the others are not This happens if the Payload Type (pt=)is something OTHER than 96. Here you can see pt=97 Looking at it in an xNode2, we can see that it is, in fact, 97 for senders 2 through 8 ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image-QYDCYUW8.png?sv=2026-02-06&spr=https&st=2026-11-01T19%3A28%3A45Z&se=2026-11-01T20%3A28%3A45Z&sr=c&sp=r&sig=U1rvE5cte%2F1zuAqi9nbubuXyN%2B8tf2jbCGPVBJvkXSY%3D) ## Changing the Payload Type Prior to xNode2, the Payload Type in xNode was not (easily) settable. But with more interoperable AoIP standards (Like AES67 and SMPTE2110-30), more configurability is needed for compatibility. The Payload type of 97 is “confusing” to iProbe, as it expects a Payload Type of 96. ### To change the Payload Type 1. In the sources list, click the AES67 option in the AoIP Type column ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image-NZHWBL7D.png?sv=2026-02-06&spr=https&st=2026-11-01T19%3A28%3A45Z&se=2026-11-01T20%3A28%3A45Z&sr=c&sp=r&sig=U1rvE5cte%2F1zuAqi9nbubuXyN%2B8tf2jbCGPVBJvkXSY%3D) > [!WARNING] > Note that when you do this, other columns like Bps, Payload Type, Address, Port, and pTime are editable. 1. From the Payload Type dropdown list, pick 96 ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image-VC5IYTTH.png?sv=2026-02-06&spr=https&st=2026-11-01T19%3A28%3A45Z&se=2026-11-01T20%3A28%3A45Z&sr=c&sp=r&sig=U1rvE5cte%2F1zuAqi9nbubuXyN%2B8tf2jbCGPVBJvkXSY%3D) 2. Change the AoIP Type back to Livewire. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image-2UEAID9R.png?sv=2026-02-06&spr=https&st=2026-11-01T19%3A28%3A45Z&se=2026-11-01T20%3A28%3A45Z&sr=c&sp=r&sig=U1rvE5cte%2F1zuAqi9nbubuXyN%2B8tf2jbCGPVBJvkXSY%3D) > [!WARNING] > Note the other fields are no longer editable but the PaylodType is now 96 1. Repeat these steps for other sources on this xNode2 2. Click Save ### Check iProbe Once you refresh the device in iProbe, you will see that the Sources now display normally. ![](https://cdn.document360.io/57e3cd80-d493-453c-9672-ad1b043dadc3/Images/Documentation/image-0VGVNNSL.png?sv=2026-02-06&spr=https&st=2026-11-01T19%3A28%3A45Z&se=2026-11-01T20%3A28%3A45Z&sr=c&sp=r&sig=U1rvE5cte%2F1zuAqi9nbubuXyN%2B8tf2jbCGPVBJvkXSY%3D)