Physical Installation

AIXpressor is a 1RU product intended to be permanently installed in a standard 19” equipment rack and secured with four standard rack screws. It is fan cooled but whenever possible, it is recommended to leave 1RU of empty space above and below the unit.

Power

Plug the IEC power cords into the AIXpressor and connect each to different mains power sources. Remember that while redundant supplies do protect against the unit losing power in the event of a PSU failure, the loss of mains supply voltage is a bigger concern. Accordingly, each supply should be fed from a different circuit equipped with adequate surge protection and fitted with an uninterruptible power supply (UPS). Each power supply has its own On/Off switch.

Important - Please click here for important information on proper grounding and other items pertaining to electrical safety.

Last updated