--- title: "PDM II - Bypass functionality defined" slug: "pdm-ii-bypass-functionality-defined" updated: 2025-06-05T15:16:32Z published: 2025-06-05T15:16:32Z canonical: "docs.telosalliance.com/pdm-ii-bypass-functionality-defined" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.telosalliance.com/llms.txt > Use this file to discover all available pages before exploring further. # PDM II - Bypass functionality defined All PDMs (PDM and PDM II) have a bypass relay that is activated by; [Click here for version 2.0.0 release notes](/v1/docs/pdm-ii-release-notes#version-200) - pressing the BYPASS button on the front of the unit - loss of power to the unit. - a soft reboot of the unit. However, the bypass is a hard relay and can only bypass PHYSICAL inputs (Analog or AES) to the same physical output type. The following table shows where BYPASS can be used during an update. | INPUT Source | OUTPUT Source | Works in BYPASS | | --- | --- | --- | | Analog | Analog | YES | | AES 3 | AES 3 | YES | | Analog | AES 3 | NO | | AES 3 | Analog | NO | | Analog or AES 3 | Any AoIP (AES 67 or Livewire) | NO | | Any AoIP (AES 67 or Livewire) | Analog or AES 3 | NO |