Record Mode GPIO Table
Note that in the iQ series of consoels, this table only applies if "Enabled" is selected as the Record Mode option.
Other consoles like Element, Fusion, and Quasar do not have these other settings.
Inputs (GPI)
Inputs are not used for this remote control. Record mode can only be enabled from the button on the console.
Outputs (GPO)
ID | Name | Pin | Notes |
GPO 1 | RECORD ACTIVE lamp | Pin 1 | Latching while in Record mode |
GPO 2 | RECORD NOT ACTIVE lamp | Pin 2 | Latching while Record mode off |
GPO 3 | Not used | Pin 3 | |
GPO 4 | RECORD pulse | Pin 4 | Momentary when entering Record mode |
GPO 5 | STOP pulse | Pin 5 | Momentary when exiting Record mode |