Operation Details
Here’s how you use Voltair’s front panel controls and LCD screen for normal operation in your station

image72.jpg

Front Panel Controls

The JOG Wheel can be turned to navigate among menu items and fields, pressed to focus on a screen area, and turned to change a selected field’s value[^27], or enter text. The escape button can be used to exit a field and save its value, or to exit a screen area and go back to the menu.

The BYPASS button can be pressed to remove Voltair II from the signal chain. It releases a pair of relays, hard-wiring Voltair II’s studio input directly to your Encoder, and the Encoder’s output directly to Voltair’s transmitter output.

Pressing BYPASS again will restore Voltair II operation if you have manually started a Bypass state. Be aware that Voltair II also goes into Bypass if it detects a problem, and during Calibration. You won’t be able to restore operation until you’ve fixed the problem or completed Calibration.

About Bypass

Voltair II’s relay bypass system provides maximum fail-safe protection against power loss or catastrophic hardware failures, and is engineered to guard against dead or unencoded air.

Bypass can be manually triggered using the Bypass switch on the front of the unit, remotely triggered using Input #1 on the unit’s 25-pin GPIO connector or synchronized with its Encoder’s Bypass function through a 9-pin cable.

Bypass disconnects Voltair II if the power fails, patching your Encoder directly into the airchain.

A watchdog circuit within Voltair II will trigger Bypass if either of its internal processors fail, or under unusual hardware conditions such as a power surge or overheating conditions.

LCD Screen

image59.jpg

This is Voltair II’s “Dashboard”, where you use various screens to control operation and monitor PPM confidence. A few features are common to every screen:

The Screen’s Name (such as Voltair-WTST: Main Screen) has two parts. The first word, in white letters, is the identifying name for this Voltair II. You can assign a unique name from the System screen, which can be helpful if you have many Voltair II’s on a network. The second part of the Screen Name (in black letters) identifies that Screen’s function.

You select which screen is active, by scrolling through the Menu on the right of the LCD.

The Menu lets you choose screens with different monitoring or control functions. Scroll through the choices with the Jog wheel, and then confirm your choice by pressing the wheel[^28].

Every screen has a dynamic Help area along the bottom. Help messages are context-sensitive and will change depending on what you’re doing. The messages are sometimes shortened to fit on one line, but their meanings are always obvious.

Voltair II’s Function Screens

Each of Voltair’s Screens displays or lets you control a different function. During normal operation, you’ll probably leave it on the Main screen most of the time[^29]. The others are for maintenance and system monitoring.

Main Screen

On the front panel, choosing either Display or Adjust on the menu shows the Main Screen:
image7.jpg

(Note that there is no “Adjust” menu item on the GUI version of this display, instead use “Switch Screen”)

  • If you’ve chosen Display, you can press jog to switch between the Voltair II Confidence Display (discussed below), a Real Time Spectral Analysis of your signal, a TVC-15 Confidence Display, and a TVC-15 Automatic Enhancement Analysis page.

  • If you’ve chosen Adjust, you can press jog to change between the Enhancement level, Voltair II Environment level and TVC-15 Environment level. (Note that the Adjust menu does not appear on the web GUI, since you can click directly on these controls to select and modify them). When you’re finished setting these parameters, go back to the Display screen to guard against accidental changes.

    When Voltair II is in bypass mode, this screen changes to a Message screen. You can still use the menu system, but the various analysis screens aren’t available.

[^27]: These operations are different if you’re controlling Voltair II from a password-protected browser: Click the computer’s mouse to choose a menu item or field, use the up and down arrow keys to select a value for the field, and press the computer’s Escape key to confirm when you’re done.

[^28]: If turning Jog selects other fields in the middle or top of the screen, rather than menu items, it means your Voltair-II is in Adjustment mode. Press Escape to get back to the Menu.

[^29]: Some stations have their processor racks visible to casual visitors. In that case, you can park Voltair II’s display on something less informative to competitors, such as the Clock screen.