Encoding Failure Warning

image5.png

If Voltair II’s analysis engine receives no valid codes over a preset time, a flashing red ENCODING FAILURE message will appear on the Main Screen, and Pin 3 of the GPIO will be pulled low. The condition is also reported on the Status Screen and written to Voltair II’s history log; a NotEncoding message is available for real time monitoring over IP.

Encoding Failures can be the result of hardware or setup problems. But they can also happen naturally when program elements don’t have enough energy to support codes; for example, during an extended silence in a live event or with some badly equalized deep voices.

Since codes can be sporadic under normal programming, it takes a while to determine that they’re completely missing (as opposed to normal pauses). Voltair II needs between 15 and 30 seconds to detect the complete absence of PPM codes and send an alarm.

Some formats normally have even longer periods that don’t support codes, so Voltair II lets you add an additional grace period before the alarm is triggered. Set Encoding Fail Grace Period in the System Screen. The time is adjustable in five second increments up to one minute.

As soon as valid codes reappear, the Failure message goes away.

Confidence Display

When the Main Screen is showing the Confidence Display, you can see how robust your station’s watermarking codes have been over the past hour. It displays code confidence, both with and without the level of Voltair Enhancement you were using at that time, measured through the Environment level you’d set.

There are two complete sets of Confidence graphics. The top row measures codes the way they’re received from your Encoder. The bottom row measures those same codes, but after they’ve been processed with Voltair Enhancement.

15-minute Horizontal Blocks
The colored horizontal blocks labeled by time-of-day (12:30, 12:45, etc.) summarize how strong your codes were during each quarter hour. Nielsen awards credit based on firm quarter-hour boundaries, so these can help you think within that context. You can use it for evaluating long program segments or how your formats change during the day.[^30]

The blocks will be in one of four colors, each with a specific meaning:

  • Dark and light green blocks mean the quarter hour carried sufficient codes. Dark green is better.

  • Yellow blocks tell you there might be problems. Your programming wasn’t supporting watermarking codes well at that time, and meters might not be able to identify your station for some panelists.

  • Red means it’s unlikely that many meters (in the selected environment, during that quarter hour) will identify your station. This can happen during some talk programming and other difficult-to-encode material.

    Red can also happen if there are technical issues, such as the Encoder being in bypass mode or your console not sending a loud enough signal for it to generate robust watermarks. So review the installation and Best Practices section of this manual before making a panic change in your programming.

    The blocks may be different colors on the upper and lower halves of the display, depending on how you’ve set Voltair Enhancement. They display algorithmically analyzed data over the quarter hour, and small differences can trigger a color change.

    A gray-shaded bar appears when not enough of a 15-minute period has yet passed to fully evaluate the period’s confidence.

    One-minute Vertical Averages

    The multiple vertical bars show the average confidence for every minute of the past hour. This interval is short enough to let you evaluate many individual program elements, such as songs or stopsets[^31].

    Like the Horizontal Blocks, there are separate sets (“Voltair Original Confidence”) for the Encoder’s output and (“Voltair Processed Confidence”) for Voltair’s Enhanced codes, and both sets are measured through the Environment level you had set for that minute. They also follow the same color code as the Horizontal Blocks. In addition, they may be displayed at ten different heights.

    The height of each bar represents more than a raw average of codes received during the minute; it actually shows the number of complete multi-code messages, as the PPM system is likely to discover them.

    The same warnings apply to short bars as to red quarter-hour blocks: they could represent gaps of specific spectral and temporal characteristics in your programming, or problems with the Encoder, or operational issues such as very low levels or dead air. Examine all these factors, and review Best Practices in this manual.

    If there are no technical or operational issues preventing successful watermarking, you might need to just dial up the level of Voltair Enhancement. In some cases, very short red bars might be telling you to look at the program format as well.

    The resulting graph gives you a detailed map of encoding confidence over time.

    Stripes

    The Vertical Average area might show a dark block with diagonal stripes, instead of the vertical bars. This indicates times when Voltair II was not processing, because it’s been manually bypassed or put into Calibrate mode.

    If you change the clock, it clears the Confidence Display

    Voltair II’s internal clock is more than a passive set of numbers on the front panel. It’s used for computing code reliability, in ways we’ve developed that work with ratings services’ time-based analysis of panelists’ meters.

    Therefore, time-of-day is an important factor. If you manually change the clock, new data won’t correlate with values previously stored in memory. Voltair II won’t be able to process the data correctly. So it starts over and clears the Confidence Display[^32], writes the new data to memory as it occurs, and uses that to draw new horizontal blocks and vertical bars. These scroll in from the right edge of the display area.

    The best way to keep Voltair II’s clock accurate is to use a Network Time Protocol server. Details about NTP and manual clock adjustment are later in this manual.

    Voltair II continuously saves operational and Confidence data in history files, and these are not erased when you clear the clock. If you want to retrieve ongoing data—or data from any previous period when Voltair II was running—use our Data Capture and Extraction features.

    Energy Meters

    The two white vertical bars, to the extreme right of the Confidence Display, measure instantaneous code energy. These are much more than simple volume meters. The upper one shows the strength of what your encoder is generating at that moment; the lower one shows the strength of codes as Enhanced by Voltair.

    The Energy Meters give you an immediate sense of how strongly watermark coding can be sent at that moment. But remember, PPM is a serial data system: individual codes have to be sustained for a specific time, and it takes multiple codes to make a message. The instant-reading Energy Meters can’t reflect the longer-term analysis used by Voltair’s confidence engine.

    Use the Energy Meters as a fast indication of whether a particular moment of your programming can support individual codes, not a comprehensive prediction of how successfully your station will be identified by the PPM ecosystem.

    If the Energy Meters show strong levels but the Confidence Display doesn’t indicate successful encoding, Voltair II might not be properly calibrated to its PPM Encoder. This can also happen if your signal doesn’t have enough extended energy to support entire messages, such as during talk shows with sporadic pauses.

Decode Interval Display

These show the amount of time, in minutes and seconds, since Voltair II was confident your PPM codes would be received by a majority of panelists’ meters. Each timer flashes green and restarts from 00:00 whenever a complete and reliable message is detected in your program stream. In a theoretically perfect system, this would occur every 4.8 seconds that you’re on the air. That’s not likely to happen with real-world programming.

  • Continuously short timings are good: they mean your programming is carrying a lot of reliable messages. The display will stay green.

  • Longer times mean your programming isn’t supporting watermarking codes as well. The display changes to yellow when ten seconds have gone by with no messages, and to red if thirty seconds have gone by. It’s less likely your station will be identified by panelists’ meters during those times. If the decode interval does not reset for several minutes, you should investigate your audio chain and program content.

  • Because the Interval Display is constantly updating, it can provide more detailed information than Voltair’s minute-wide graph bars. This gives you an immediate comparison of the encodability of different types of programming.

    There are also three separate Decode Interval control outputs on the unit’s back panel[^33]. You can use them to send external warnings to operators, or to start other functions. These rear-panel outputs monitor the signal including any Voltair Enhancement you’ve set. They trigger when one minute, two minutes, and five minutes have gone by with no decoded messages.

[^30]: Blocks can be displayed in AM/PM or 24-hour formats, as set on the Clock menu screen.

[^31]: If you want to capture these measurements on an even shorter basis, or hold onto them for later comparison with ratings reports, use our optional Data Capture and Extraction feature. It gives you confidence readings at 4.8 second intervals, either as they are happening, or for any broadcast period that’s gone by.

[^32]: If you want to save the Confidence Display before changing the clock, log in from a connected web browser and screen-capture or print the page in your computer.

[^33]: Control outputs and inputs are logic level and opto-isolated, on a DB-25 connector. Wiring details can be found later in this manual.