# Main Screen Parameters and Analyzers
Parameter Settings
These display your settings for Voltair Enhancement, and let you see how your station’s encoding will perform under different Environment levels.
-
If Display is highlighted at the top of the Menu area on the right side of the LCD, the parameters are read-only. This protects them from accidental changes.
-
If Adaptive Enhancement is enabled under the TVC-15 menu item, the Enhancement control becomes read only, dynamically displaying Enhancement levels.
-
To change a setting, turn the jog wheel to select Adjust on the menu, then press the wheel. The rest of the menu will turn dark, and one of the Main Screen parameters will be highlighted.
General JOG Wheel and Escape button behavior[^34]:
-
Turn the Jog wheel to select the parameter you want to change, and press the wheel to edit its value. Now you can turn the wheel to adjust the parameter or scroll through its options.
-
When you’ve got that parameter the way you want it:
-
Press Escape to save that setting. Then Jog to select other parameters on this screen.
-
Or press Escape twice to leave Adjustment mode. The full menu will be highlighted once again, and the Jog wheel can be used to select any menu entry.
Enhancement
Voltair analyzes the PPM signals your Encoder hides under program audio, and applies advanced signal processing to make them stronger. Enhancement levels can be set from 0 (original code level, with no enhancement) to 24 (a lot of processing), or they can be automatically adjusted using Adaptive Enhancement, found under the TVC-15 menu item.
If you change the Enhancement level and it snaps right back to a previous setting, Test Switching may have been enabled in the Presets screen. This function automatically cycles through pre-set levels, for long-term tests to correlate Voltair’s Enhancement with your station’s ratings reports. There’s more about this feature in a later section. Another possibility is that one of the Preset GPIO inputs is being held to a logic Low.
Choosing the right Enhancement level is not trivial. It depends on your programming and station goals. See page “Using Voltair Enhancement” for a discussion.
By adjusting Enhancement slowly, and seeing its effect on Voltair II’s Confidence Display, you can begin to get a sense of the best setting for specific program material. You can also conduct a scientifically structured test of Enhancement levels: details are in the “Testing Strategy” section.
Three different Enhancement levels can be preset through Voltair’s Enhancing menu, and triggered by logic-level inputs on the rear panel. This can help you apply different enhancement presets for different dayparts, or install a remote switch for difficult program elements.
Environment
Ratings success has to include a full understanding of the PPM ecosystem. Codes don’t magically fly from the Encoder to panelists’ meters; they have to survive the noisy environments where panelists might be listening. Different types and amounts of noise affect watermark codes in different ways. Voltair II gives you a way to compensate for a listener’s environment when doing its Confidence measurements by injecting noise into the analysis engine to bias the confidence display.
You can adjust noise simulation levels for both the Voltair Enhancement (Voltair Env.) and TVC-15 measurement (TVC-15 Env.) between -60 dB and +10 dB, with 0 dB representing noise levels that are essentially as loud as the station’s programming. We included the positive values because, even when the noise is louder than station programming, listeners may still be able to understand speech or pick out familiar songs.
Real Time Spectrum Display (RTA)
The presence of continuous energy in roughly the 1 kHz – 3 kHz range is one of the most important factors contributing to successful code generation. Many music styles have this energy; much spoken word does not. But you can’t rely on generalities: Within a specific style, some songs can be very friendly to PPM encoding while others are antagonistic; voice encoding may depend as much on the delivery style and pacing as on the talent’s ‘pipes’.

So we give you a spectral meter. When you’ve selected Display on the menu, pressing Jog advances the Confidence Display to show the RTA.
This is more than the simple spectrum display you might find on a boombox or mp3 software; it measures energy at specific frequencies used by the PPM system. The blue area is an instant-reading meter. The red line freezes Peak values and holds them for a second, to make them readable.
As you work with the RTA, you’ll begin to recognize patterns in your program elements. Generally, speech will have higher energy toward the lower frequencies and the lines will show more vertical movement while talent is talking. Music—depending on the style—will be more evenly distributed; the lines will be more stable as notes are sustained. While there are other factors as well, signals that display with high and consistent lines will have a better possibility of encoding.
TVC-15 Graphic Displays
The addition of TVC-15 capability in Voltair II provides an independent analyzer for watermarking presence, and can be viewed on two different displays: a TVC-15 Confidence Display, and a TVC-15 Automatic Enhancement Analysis Display. Pressing Jog advances the Confidence Display to toggle from the RTA screen to the TVC-15 Confidence Display

Pressing Jog again will advance to the TVC-15 Automatic Enhancement Analysis Display:

[^34]: These controls have additional functions when you’re entering text on the LCD.