# Voltair II and Your Ratings
Voltair II and Your Ratings
It’s all about your listeners. Your people, your programming, your gear… everything you do is focused on building and retaining your audience. That’s how you stay in business.
There’s a direct link between Nielsen’s reports about the size and composition of your audience, and your station’s revenue. Nielsen bases these reports on listener panels, where each panelist represents many people in your market.
In PPM® markets, audiences are measured by panelists wearing portable meters. These meters listen for digital codes hidden in your station’s audio. The codes, called “watermarks”, are unique for each station. They’re both generated from your program audio, and hidden beneath it. Thousands of codes are created in the course of an hour, and this massive redundancy helps assure that these codes are picked up by the meters. Error correction algorithms are supposed to fill in the blanks when codes are missing or weak.
But no system is perfect. An inherent trade-off exists between how robust a code can be—that is, how well it can be picked up under normal listening situations—and its audibility. We also know now that not all programming encodes equally well. Different announcers or songs have different sonic properties. Silence never encodes. Some formats, such as Talk, may provide fewer opportunities for robust encoding when compared with denser music formats. In addition, some noisy listening situations (such as driving in rush-hour traffic) can interfere with codes being heard by the meters. Panelists might be enjoying your station, but if their meters don’t register your code, you won’t get credit for them.
If your codes aren’t detected, “edit rules” attempt to fill in the gaps. These rules are a form of error correction based on statistics, and may or may not be successful. More codes let these paint a more complete picture, so it’s obviously best to have your codes arrive properly in the first place.
In other words, it’s an ecosystem: every aspect of your programming, the PPM encoder, panelists’ listening environments, their meters, and subsequent data editing all have to work correctly for ratings to be accurate. There are so many variables and random elements that nobody can claim the ratings system has perfect accuracy, all the time.
For most stations, income is directly related to these ratings. With so much riding on a few panelists, every code and every meter needs to count.
That’s why we created the original Voltair, and have improved it with Voltair II.
Voltair II is designed to give you more confidence that your station is actually getting the end-to-end PPM system performance that Nielsen intended, so you get the ratings you’ve earned. It displays how well your programming encodes, moment by moment. You can see the effects of programming changes—even different songs or announcers—in real time.
Voltair II applies advanced signal processing to enhance the robustness of your station’s codes. Having robust codes means PPM meters in the field are more likely to detect them. It includes automatic support for scientifically structured tests of how well its signal processing correlates with meter count. You do these tests on your own, comparing controlled changes in Voltair processing with the data in your station’s Nielsen reports[^1]. Learn more about Toggle Testing later in this manual.
New since the original Voltair are two key features:
Voltair II integrates TVC-15 capabilities, providing a completely separate analysis engine that powers Adaptive Enhancement. This solution listens to watermarking tones, pushing for more enhancement when needed, and backing off when source material already supports strong encoding. In this respect, Adaptive Enhancement can be thought of as an automatic gain control (AGC) for Voltair Processing.
Voltair II adds our new Pascal Algorithm. For context, certain types of audio, especially certain dry voices and halting vocal delivery styles do not encode well. In such cases, the PPM algorithm can not generate watermarks with sufficient energy in critical bands, and the original Voltair could not enhance what was never there in the first place. Pascal is an audio conditioning processor designed by Frank Foti to make difficult-to-encode audio (such as dry voice) more conducive to watermarking.
Voltair II’s Data Capture and Extraction tools let you do even more precise analysis, and are now included as standard features:
-
They give you continuous reports of ratings confidence. You can determine how well individual songs and segments, announcers, and even promos and ads are encoding. You’ll gain fresh insight into how programming decisions affect successful encoding.
-
These reports include encoding confidence numbers both with and without Voltair II’s advanced signal processing. This helps you find the best settings both for Voltair II, and for any other processing that can affect encoding.
-
Data can be sent to your computer in real-time. Or you can recall detailed confidence histories from earlier that day, or from any previous period when Voltair II was connected.
-
You can examine raw data from Voltair II’s deep internal history files, or export comma-separated-value lists of raw data recorded every 4.8 seconds for your own analysis.
-
For ultimate understanding of your ratings picture, you can correlate Voltair II’s reports with your program logs and with ratings numbers as delivered by Nielsen. You’ll get real-world confirmation of how your programming decisions affect your numbers.
As you use Voltair II to help get credit for all the ratings you’ve earned… -
You’ll be able to monitor the health of your station’s encoding in real time, so you’ll always know that function is running optimally.
-
You’ll be able to simulate how different noise loads affect the strength of encoding, using your broadcast signal. This information can help you fine-tune programming and processing for different dayparts.
-
You’ll get more confidence in the end-to-end watermarking performance for your station. You’ll understand how programming decisions can affect this accuracy.
-
Voltair II even warns you when encoding has failed, either because of program limitations such as silence, or because of Encoder hardware issues. You can set a grace period before alarms are triggered based on your own programming.
Voltair II doesn’t increase the number of your listeners.
But it helps give you confidence your listeners are correctly counted.
Ratings, Programming, and Flying Blind
Radio ratings has been called “a game of inches:” winners and losers can be decided by the thinnest of margins.
Station management teams have always carefully monitored listener data, and tailored their programming to maximize ratings and revenue. But since the introduction of electronic measurement, this tailoring has gotten much more pronounced. Program directors report making more dramatic changes than ever before. Some formats have fallen from favor, dayparts have been moved, local breaks have been reduced, and programming clocks have become more rigid in response to the precise quarter-hour boundaries of PPM credit. Imaging and other elements of a station’s sound have been designed with hopes of the station being recognized by more panelists’ meters. Engineering decisions like processing and airchain device order have been changed in service to PPM
But with ratings provided on a delayed basis, many efforts to optimize programming for maximum code credit have been trial and error. Program directors have had little insight into which efforts are helping, and why.
Voltair II gives you reliable, confirmable measurements of how well your station’s programming is encoding in the real world. It gives you new tools to drive ratings and revenue.
[^1]: Your station’s competitive information never leaves your control. You never have to trust anyone else with your data, and can judge for yourself how well Voltair II is working.