03 GPIO Pinouts and Wiring

Prev Next

# GPIO Pinouts and Wiring

GPIO (25-Pin DB25)
Six parallel control inputs and eight parallel control outputs appear on a female DB-25 connector. Pin assignment is as follows:

input pin signal Notes
1 25 Toggle Bypass Toggles Voltair II bypass mode, equivalent to front panel button
2 12 Load Low Preset Sets parameters to settings stored to Low Preset values on Presets menu item.
3 24 Load Medium Preset Sets parameters to settings stored to Medium Preset values on Presets menu item.
4 11 Load High Preset Sets parameters to settings stored to High Preset values on Presets menu item.
5 23 Bypass ON Turns bypass on
6 10 Bypass OFF Turns bypass off

Inputs should be pulled low momentarily to activate. Connect inputs 2, 3 and 4 to an automation system to change Presets at different dayparts, or to test Voltair II’s effectiveness using Test Enhancement Swaps driven from your automation system[^48].

output pin signal Notes
1 19 Voltair Bypass Indicates Voltair II is in Bypass
2 6 Decode >= 1 Decode interval is greater than one minute
3 18 Decode >= 2 Decode interval is greater than two minutes
4 5 Decode >= 5 Decode interval is greater than five minutes
5 17 Preset = Low Settings now equal values stored under the Low Preset on the Presets menu item
6 4 Preset = Medium Settings now equal values stored under the Medium Preset on the Presets menu item
7 16 Preset = High Settings now equal values stored under the High Preset on the Presets menu item
8 3 Not Encoding Alarm There is a user-adjustable “grace period” before alarm triggers, settable on System menu item

Outputs are held low for as long as operational state exists. You can connect outputs 2, 3 and 4 to your automation system for logging of Automatic Enhancement test switching.

other pins Designation
1, 9, 14,15, 21, 22 no connection
2, 20 Ground
7 output common
8 +5 VDC 200 mA Max
13 input common

Inputs and outputs are opto-isolated for easy interface to other equipment. A +5v supply and ground are also brought out to the DB-25 for simple remote controls using pushbuttons and LED status readouts. The supply can provide 200 mA, more than adequate for 8 LEDs and 6 logic inputs. Total draw should not exceed this value. This supply is protected by an internal, self-resetting thermal circuit breaker. If this breaker should trip, power off and allow several minutes for it to reset.

  • Inputs require at least 6 mA flowing from the input common (pin 13) and the individual input circuit pin.

  • Outputs can carry up to 25 mA, up to 30 V DC per channel, between the individual output circuit pin and output common (pin 7).

    Simplified schematic of control arrangement, with basic pushbutton control and LED readout:

    Use the jumpers shown as thick gray lines for simple pushbutton and LED remote. * indicates individual DB-25 pins for separate inputs and outputs, as per the tables.[^49]

    AC Power

    Connect to 60 cycle source between 100 and 240 volts. Voltair II is internally fused at 5 Amp, but will typically draw much less: peaks of about 100 watts on startup, and 50 watts when running.

    When you turn Voltair II ON, it goes through a startup procedure of about 30 seconds. The system’s fans will run at high speed during startup, but then slow down to normal operating level. Multiple cooling fans help ensure the processing systems stay at optimal operating temperature, ensuring a long life, and significantly lowering risk of heat related device failures.

[^48]: These tests can be driven internally by Voltair II if desired. Complete details on this kind of testing can be found under the “Finding the Best Enhancement Level” section.

[^49]: Although typically not necessary with most digital logic inputs, a 10K pull up resistor between Voltair II’s internal +5v logic supply (DB-25 Pin 8) and the desired status output pin may be required with certain broadcast remote controls where an analog metering input is used as a digital status input.