01 Calibration Issues

Prev Next

# Troubleshooting Calibration Issues

Troubleshooting and Updates
Voltair II is solidly built, with rigorously tested hardware and software and collective years of successful run time. Nonetheless, no electronic equipment is immune from occasional problems. These pages will help you identify which ones can be fixed quickly and locally, and which require your contacting us.

In an emergency, you can reach our Support Team anytime by submitting a support request at https://www.telosalliance.com/support-request or by calling +1 216-241-7225 and selecting option 2.

Voltair II has an extensive internal logging system, engineered to ensure system integrity and help us get to the bottom of any problem quickly. When contacting customer support, you may be instructed how to retrieve log files so they may be emailed to us for analysis.

For billing questions or other non-emergency technical questions, email Support@TelosAlliance.com or call +1 216-241-7225 between 9:00 AM - 5:00 PM USA Eastern Time, weekdays. There’s full contact information at the end of this chapter, and in the last section of this document.

Calibration issues

If you have any problems successfully calibrating please check the following items:

  • Make sure both the PPM Encoder and Voltair II are plugged in, and that Voltair II is powered on (there is a power switch on the rear panel, adjacent to IEC connector)

  • Make sure the PPM Encoder is not in Bypass

  • Check that audio cabling to and from the encoder is correctly installed: no channel flipping, no unbalanced cabling, no polarity reversals. Voltair II does a rigorous cable test on startup, alerting you if you need to address cable related errors.

  • Make sure there are no electronics between Voltair II and the Encoder. It must be an uninterrupted cable connection. Analog/Digital converters or signal routers introduce latency that makes Voltair II calibration and operation impossible.

  • Make sure that Audio Mode is correctly set to Mono or Stereo from the Adjust menu choice on the unit front panel.

  • Digital Voltair II connections should be 32 kHz, 44.1 kHz, or 48 kHz sampling; 2-channels interleaved AES/EBU; 16- or 24-bit; 110Ω balanced XLR wiring.

  • A few settings may also be necessary on the Nielsen Encoder:

  • Digital PPM Encoders must have their input selector set to XLR.

  • Some Analog Encoders may have a termination switch. Set this to 600 Ω

    If Voltair II reports cable problems during calibration, and cables have been checked with no errors found, it’s possible Voltair II is in an unstable state because of an interrupted calibration. If so, power-cycle both the Encoder and Voltair II. Then recalibrate.

    If all the above seem correct but calibration still fails after several attempts, try switching to a different encoder (for example, replace your Primary unit with its Backup). Voltair II verifies Encoder audio performance during Calibration: if a specific Encoder won’t Calibrate, check Voltair II’s screen for information[^50].

    If you can’t calibrate your Voltair II to any encoder, call customer support for assistance.

[^50]: Any piece of electronic equipment has components that can drift out of spec over time, and drifting within an encoder may cause timing or noise issues.