01 Quick Setup Guide

Prev Next

# Voltair II Quick Setup Guide

INSTANT GRATIFICATION[^12]

Voltair II Quick Setup Guide

This section explains, very briefly, how to get Voltair II up and running in your airchain.

If you are replacing an older existing Voltair with Voltair II, know that Voltair II was designed to be a 1:1 replacement for its predecessor. Cable connections and rack locations can be re-used, and the unit simply swapped out. That said, you may want to check cable conditions before installing your new unit.

Voltair II is a versatile device, with other setup options we couldn’t include here. So these instructions might not be best for your specific setup. More information can be found in the Installation chapter of this manual. Details on remote controlling Voltair II via web browser or GPIO may be found in the Remote Control section. .

Similarly, this section has only generalities about Voltair II operation. Optimum settings and interpretation depend on your program material and station’s goals. There are full discussions elsewhere about operational settings, the Confidence Display), TVC-15 use, and using optional Data Capture and Extraction. For more about the overall watermarking environment, see “Exploring the PPM Ecosystem, later in the manual. .

In other words, we urge you to read—or at least scan—the rest of this manual. You’ll learn the best ways to use Voltair II in your station, and how to get the most reliable ratings possible.

Installation

1. Choose analog or digital Voltair II

Voltair II is completely digital inside, of course. These two model designations refer to Voltair’s input and output connections: Voltair II, like its predecessor ingests either AES/EBU digital audio, or balanced +4 dBu (nominal) analog audio.

The connection method must match your Nielsen Encoder. Either both Voltair and the Encoder must use analog jacks, or both must use digital.

There must be a direct cable connection between Voltair II and the Encoder. Any intervening electronics, such as a Digital-to-Analog (DAC) or Analog-to-Digital (ADC) converter or an active router, will introduce variable latencies that interfere with proper functionality. Do not put any “extra” device between Voltair II and the encoder you will be pairing it with.

If you must convert between analog and digital in your plant, do it before Voltair II’s main input, or after its main output. Don’t interrupt the wiring between Voltair II and the Encoder, described in step 3 below.

2. Give it a home

Mount Voltair II in a rack with appropriate power and ventilation.

For easiest installation and operation, Voltair II should be physically close to your Studio Grade (“PPM”) Encoder, EAS encoder, and your Telos Alliance Omnia or other airchain loudness processor. Note that Voltair II works exclusively with hardware PPM encoders and is incompatible with software (SDK) based encoders residing within a processor.

3. Connect Voltair II to the Encoder

Run appropriate cables between Voltair II’s XLR Encoder connectors and the Input and Output of your Nielsen PPM Encoder. If your plant is mono with analog connections, use just the Left channel.

image33.png

Some analog Nielsen Encoders include a “High / 600” termination switch at their inputs. This selects whether the inputs are bridging (10kΩ impedance), or apply a 600Ω load. If your Encoder has this switch, you’ll get the best results and most accurate gain staging by setting it to 600.

4. Put it in your air chain

How you connect the Voltair II and Encoder pair with other equipment in your transmitter chain, such as processors, can have a major effect on watermarking integrity.

Most effective
Most stations use multi-band dynamics processors to boost perceived loudness and create a signature sound. These processors can also help the PPM system, by boosting spectral energy between 1 kHz and 3 kHz[^13].

Newer Omnias and some other loudness processors have an insert or patch point. This lets you interrupt the connection between the unit’s audio processing and its final clipper and stereo generator. If you insert the Voltair II / Encoder combination at this point and carefully tune Voltair II’s enhancement, you can get the most reliable encoding for your program material. Specific instructions for Omnia processors and presets can be found in the “Using Voltair II with Omnia” chapter. Please note that if you plan to use the Pascal process in Voltair II, patch point installation is highly recommended.

image11.png

You may also choose to put your EAS Encoder after Voltair II in the same insert loop (gray background in the drawing). This assures that emergency signals won’t be affected by any processing[^14].

Alternative Hookup
If your processor doesn’t have an insert point, you can put Voltair II and its Encoder ahead of its input.

image2.png

The Encoder’s functionality can be somewhat sensitive to input levels, however, and this scheme won’t give the encoder protection if studio levels vary widely. So if your installation doesn’t have a transmitter processor insert point available, urge your operators to avoid extended periods of low levels. If you’re using an additional compressor or gain-riding device ahead of the main loudness processor as part of your signature sound, put Voltair II between it and the main processor. In an ideal situation, the airchain’s signal flow should be Loudness Processor » Voltair (with its PPM Encoder) » EAS Encoder » transmitter.

Both Voltair II and the PPM Encoder are designed to operate as unity gain devices, with standard levels between +4 dBu and +8 dBu nominal for an analog setup, or between -20 dBFS and -12 dBFS for a digital one. Operating at other levels can add noise or distortion, and sacrifice coding integrity.

Test the wiring by leaving Voltair II powered off and sending your normal signal through to the transmitter. When Voltair II is off (or in Bypass mode), it uses relays to route its input directly to the Encoder, and the Encoder output directly to Voltair II’s output jack. So the signal should flow, and the Encoder should continue to add its PPM codes to your program.

5. Add the other connections

Connect Voltair’s Network jack to an appropriate data network. This connection is used to synchronize Voltair II’s clock to an NTP server, for browser-based remote control, for Data Capture and Extraction use, and for maintenance. It doesn’t carry IP-based audio.

Voltair II will attempt to register with your network’s router via DHCP. If your network uses some other scheme, setup instructions are in the Operations section. Once Voltair II is on your network, we recommend changing its default passwords for security.

The GPIO connector provides basic control, preset access, and warnings when there is low confidence in your encoding. Details are in the GPIO section.

For the time being, leave Voltair II’s 9-pin Encoder Bypass Monitor disconnected. It’s designed to mate with a matching Bypass Monitor jack on the Nielsen encoder. But there are operational considerations, and in many situations Voltair II’s built-in alarms will tell you more about the Encoder performance.

Calibration and Setup

Voltair II must be calibrated for the specific Hardware PPM Encoder it’s attached to. Each encoder has slightly different characteristics, and without this calibration, Voltair II’s functions cannot work properly: you won’t be able to analyze or enhance your station’s watermarking codes successfully.

The calibration process is automatic, and takes about five minutes. Voltair II will send specialized test signals into your Encoder and measure the result. During this time, both Voltair II and the Encoder are functioning but offline: they get bypassed, no PPM codes are generated, and your program signal gets sent directly to the transmitter.

After calibration, Voltair II puts both devices back online. Voltair II can then measure encoding confidence, and you can apply whatever level of Enhancement you select.

Complete calibration instructions follow below in step 8, as well as in article 10 of the Operation Details section.

Recalibration is generally required only if you replace Encoders. But this includes if you replace your station’s primary Encoder with its backup unit: even if your backup encoder carries the same identification codes, it requires a fresh calibration. You may also want to use the Calibration function if you are concerned about your encoder’s audio quality; during this process, Voltair evaluates the encoder for noise and distortion.

Front Panel
Most Voltair II operations can be controlled from the front panel[^15]. Some functions, such as calibration can only be performed from the front panel.

image34.png

The Jog wheel can be turned to scroll through menus and fields on the screen, highlighting each. It’s also a button: if you press it, it acts as a Confirmation button to select the highlighted menu or screen area. Once you’ve Confirmed a selection, turning Jog will scroll you through its possible options.

The escape button returns you to the next higher level. If you’ve been entering values in a field, it stores the value, exits the field, and takes you back to selecting other fields in the area. If you’ve been selecting fields, it takes you back to selecting menus on the right side of the screen.

The bypass button releases relays to completely take Voltair II out of the circuit. In bypass, Voltair II’s input is routed to the Encoder, and the Encoder’s output is routed to the transmitter.

There is a power switch on the rear panel, but in normal operation you’ll never touch it. Turning off the power also releases the bypass relays.

6. Power up

Turn Voltair II on. After an initial boot sequence of approximately 30 seconds, the front panel LCD will look like one of these two pictures:

image45.png

The screen on the left will appear if this particular Voltair II has never been calibrated for any Encoder. The screen on the right appears if this Voltair II has been calibrated elsewhere, either for testing or because the unit has been moved from another installation.

If the screen on the right appears, Voltair II may appear to be processing audio properly. You might also see a large flashing ENCODING FAILURE warning if there is no program audio. In either case, Voltair II doesn’t know you’ve attached it to a different Encoder. Press the front panel bypass button, and continue to the next step.

7. Check for mono or stereo

In mono analog stations, Voltair II must be wired using the left channel only for correct operation. In mono digital stations, the left channel of the AES/EBU interleaved signal should be used. In both analog and digital installations, Voltair II must be properly configured for mono or stereo before use. Note: this operation can only be performed from the front panel.

Turn jog to select System from the menu on the left side of the LCD. Press the wheel to Enter the screen, and press it again to edit the Audio Mode setting.[^16]

image56.png

Turn the wheel to select either Stereo or Mono (A only). If this is not set correctly, analog systems may exhibit additional noise, and digital Encoders might not even generate codes.

While you’re looking at this screen, verify that Voltair II Program Output is set to Enhanced Audio. This is the default, but it may have been changed if someone unlocked the program output via Voltair’s web interface (page 66).

Press ESCAPE twice to save your choice and return to menu selection.

8. Calibrate

This automated function is the most important step before you can successfully use Voltair II.

Make sure the PPM Encoder is set for normal operation, and that the Encoder is not in Bypass mode. Use jog to select Voltair II’s Calibrate menu, and you’ll see a message “PRESS WHEEL to calibrate Voltair II”.

Press Jog to initiate, or turn the Wheel to select some other menu item. If you press Jog from this menu, a warning dialog will appear.

Press Jog to start the pre-calibration check, or escape to cancel[^17]. If you press jog, Voltair II and your Encoder will be taken out of the airchain and Voltair II will test the cables linking it to the Encoder. Program audio will continue to be output, and you can continue to broadcast without PPM codes while this is going on. (If leaving the unit in the airchain during calibration, we suggest you perform this in overnight hours).

Voltair II then waits for your final confirmation. Press jog again to start. A progress bar tracks calibration, which takes about five minutes. It is important not to interrupt the calibration process. When the process is finished, Voltair II begins analyzing and enhancing your PPM codes.

You can check that Calibration is complete on the Status screen. Highlight the bottom entry on the menu on the right, and press jog. The Calibration date should show today’s date. If you have just finished Calibrating and the wrong date appears, check the Clock screen and make sure you’ve set the clock or configured Network Time Protocol.

Some common wiring or operational errors, such as reversed analog channels, polarity errors in balanced wiring, or leaving the Encoder in its own Bypass mode, will cause calibration to fail[^18]. Most of these are detected automatically, and hints for fixing them will appear on Voltair II’s screen. Correct them and try again. If calibration continues to fail, check your setup. Contact customer support if you can’t resolve issues.

9. Start Using Voltair II!

Once Voltair II is calibrated, it’s now ready to measure watermark encoding confidence. It’s ready to enhance your codes to assure best performance. It’s even ready to use off-line to evaluate new songs or other program elements for friendliness to the PPM ecosystem.

If you’re not sure of all the things Voltair II can do, go back to the Overview.

[^12]: We designed this section for those of you who like dessert first. Please go back when you’re finished, and read the more nutritious part of this manual.

[^13]: The frequencies are approximate, and other important factors such as temporal distribution have a major influence on watermark success.

[^14]: Voltair II’s processing does not affect EAS data bursts, and won’t affect downstream relay stations. However, watermark encoders may react to the alert tone and can cause distortion.

[^15]: Most functions can also be controlled from a password-protected web browser. A few functions require transferring files to or from Voltair II, and must be done with a connected computer.

[^16]: If it doesn’t work this way, you might have inadvertently pressed some other button while installing. Turning the unit off and on again will get you back to this point.

[^17]: Pressing CANCEL puts Voltair II into Bypass mode. Voltair II shouldn’t be used until Calibration has been completed.

[^18]: If calibration is interrupted because of a power failure or other unexpected event, Voltair II might not realize that fact after power returns. Essentially, the machine will behave as if you’ve just installed it from another location, and proper operation is impossible. Go back to the first step of Calibration and Setup, and try again.