# Calibration, Status, and Program Testing
Calibrate Screen
This screen allows you to initiate the Calibration process.
.png?sv=2026-02-06&spr=https&st=2026-11-26T03%3A21%3A22Z&se=2026-11-26T03%3A35%3A22Z&sr=b&sp=r&sig=cPizGKidhH80zZhs7Ll8BYvVDtggBaRj46aWrnawwuU%3D)
This automated function is the most important step before you can successfully use Voltair II.
Make sure the PPM Encoder is set for normal operation, and that the Encoder is not in Bypass mode. Use jog to select Voltair II’s Calibrate menu, and you’ll see a message “PRESS WHEEL to calibrate Voltair II”. A confirmation warning screen will appear:

Press **Jog **to start the pre-calibration check, or escape to cancel. If you press jog, Voltair II and your Encoder will be taken out of the airchain and Voltair II will test the cables linking it to the Encoder. Program audio will continue to be output, and you can continue to broadcast without PPM codes while this is going on. (If leaving the unit in the airchain during calibration, we suggest you perform this in overnight hours).
Voltair II then waits for your final confirmation. Press jog again to start. A progress bar tracks calibration, which takes about five minutes. It is important not to interrupt the calibration process. When the process is finished, Voltair II begins analyzing and enhancing your PPM codes.
Voltair II must be calibrated to the specific Nielsen Encoder you’re using, so this operation should be done when you install or move the Voltair II or the encoder.
Status Screen

This lets you check Voltair II’s status and operational state. The screen reports changes in real-time. It’s also read-only; to change the NTP and IP settings, you’ll have to go to their specific screens.
The Last PPM timestamp line displays in HH:MM format the internal time code, in the local time zone, of the most recently-received PPM encoder message, which is sent out with Station ID’s as part of each watermarking message. If no messages have been received for the last two minutes, it will show "- none -".
The Calibration date and time are set automatically during calibration (see previous section). If the process is aborted because of some unforeseen event, such as a power outage, this data can get out of sync. Power-cycle the unit, and calibrate again.
The IP Address should be noted if you plan to log in remotely; it’s where you’ll point your browser. This address is displayed correctly, regardless of whether you’re using DHCP or a static IP address. The Mask, a number that follows the IP Address, is used for network configuration.
The MAC Address identifies Voltair II’s networking hardware, and is unique for each system. You may need this to enable security features on your network router.
The GPIO Inputs are for testing remote controls and automation system interfaces. These six characters report logic levels on individual pins of the rear panel DB-25 connector, and change from 0 to 1 while being triggered.
Encoding Status reports if there’s an Encoding Failure, after the Grace Period has passed.
Temperature and Version are used for maintenance.
Testing Individual Program Elements
You can use an off-line Voltair II and Encoder to evaluate songs, sweepers, or other short content.
This can be a good use for spare hardware you may be keeping for emergencies. The standby Voltair II and Encoder can be in your rack room or transmitter location, ready for on-air use; during its downtime, the Program Director or producer can run Voltair II remotely from their office or studio, with any standard computer.
A few considerations for this kind of use:
-
PPM ratings can look at a full quarter-hour block. A single song—even one five minutes long—won’t give Voltair II enough data for a proper statistical analysis of just that element. Assemble a loop with at least fifteen minutes of the test material, preceded by a minute of pink noise at normal program level. When you’re testing, back-time the noise so that content starts within a few seconds of a quarter-hour block.
-
You can use Voltair II and its paired Encoder for off-line analysis of programs and elements, but you should never use it to pre-record PPM codes for later playback. Nielsen includes a timecode stamp as part of the code that Voltair II enhances, and checks that code against real time when analyzing meter data. Codes must only be added in real-time.
-
There must be a direct cable connection between Voltair II and its Encoder, and Voltair II has to be calibrated for its specific Encoder hardware. But you can route Voltair II’s Studio input and Transmitter output to other locations via audio router, audio over IP, or any other way you want. So sending the audio you want to evaluate across a facility—or even to a remote site—isn’t a problem[^43].
[^42]: Voltair II requires a “copper connection”: direct electrical continuity between the Encoder and itself. A conventional plug-and-jack patchbay supports this. But don’t use an electronic router or switcher, or an audio-over-IP setup. These introduce latency that can make Voltair II analysis and Enhancement impossible.
[^43]: But audio quality might be an issue. Psychoacoustic compression schemes (like mp3) can remove details that the PPM encoder is listening for. If you’re shipping audio to a remote Voltair II / Encoder pair via AIOP or other packet system, use the highest quality the system will support.