# About Calibration

About Calibration
Each PPM Encoder has a unique encoding signature belonging to its assigned broadcast station. To function correctly, Voltair II must be paired to a specific PPM Encoder and successfully synchronized to it through a calibration process. Since multiple encoders assigned to a single station can have slightly different characteristics, you must recalibrate whenever you change encoders.

The calibration process takes about five minutes, with percent of completion indicated by a progress meter. During calibration, the attached PPM Encoder is bypassed and watermarking is suspended. Program audio will pass through unaffected. The calibration process should not be interrupted by pressing Escape or Bypass.

No “partial credit” is given if Calibration is ended prematurely. We recommend calibrating during non-peak hours, and allowing the process to complete: a full calibration cycle must take place before Voltair II can be used.

When to Calibrate
When you power up Voltair II for the first time, you will be prompted to perform an initial calibration. At the conclusion of the first successful calibration, you should not have to recalibrate unless you move your Voltair II to a different PPM Encoder, or change the sample rate of a digital Voltair II/Encoder pair.

If you connect your Voltair II to a different station’s PPM Encoder without recalibrating, or install a Voltair II that had been used with another Encoder, the unit will appear to function. But Confidence Measurements and Enhancement will not work properly.

In no way can Voltair II be calibrated to one Encoder, then moved to another Encoder without recalibration!

Calibrating in the Airchain
During calibration Voltair II routes program audio through its input and output stages, but bypasses its main processor and the PPM Encoder. This suspends watermarking. For best practice, we recommend patching your backup PPM Encoder into the airchain during calibration so ratings are not impacted. After about five minutes, when calibration is complete, you can re-patch the primary Voltair II/Encoder pair into the airchain.

If your backup encoder is not available and you have to calibrate the primary PPM Encoder in the live airchain, we recommend this process only be done at off- peak times (generally, overnights between 9 PM and 6 AM). Please be aware that calibrating a PPM Encoder in the airchain may set off a confidence monitor alarm.

Once Voltair II successfully calibrates, it will automatically switch to its main screen and begin operation.

If you are calibrating a digital Voltair II, you must supply a stable AES digital signal to Voltair II’s input, running at your house sample rate. Calibration is sensitive to sample rate changes, and Voltair II must be calibrated using your facility’s default clock rate to assure optimal performance.

If you are using a digital Voltair II and Encoder, and need to change your house sample rate, you must recalibrate Voltair II.