Updating your Omnia.9sg software is done using the NfRemote client. This procedure assumes you have already installed and have access to your Omnia.9sg. Please refer to the Omnia.9sg manual for instructions on how to set up NfRemote
SCOPE
This update applies to the following products;
2001-00418-000: Omnia.9sg Stereo Generator
2001-00420-000: Omnia.9sg Stereo Generator (with RDS)
2001-00494-000: Omnia.9sg Stereo Generator (with Auxiliary Input Processing)
2001-00495-000: Omnia.9sg Stereo Generator (with Auxiliary InputProcessing + RDS)
Backup your current settings
Before proceeding with any update we suggest making a backup of your current configuration. To do so use the NfRemote software.
Select System
Then chose System Configuration
Chose Backup
Then choose Backup (Download) Configuration and save this file to a location on your computer.
IMPORTANT NOTES - PLEASE READ BEFORE UPDATING
In some cases, a full power cycle may be required following the software installation in order to re-establish remote access. For this reason, It is recommended that you do NOT attempt this update remotely. Perform this update only while you are physically in front of the unit.
Software Update Procedure
Please download version 3.30.73 from here and save this to a location on the computer you will use to perform the update.
The file must be used as downloaded. Do not use any software to unpack or unzip the file.
There are two ways to update the software in your unit. One is using the NfRemote software and the other is using a USB flash drive plugged into the front panel USB port.
Updating by USB flash Drive
Copy the update file to the root of the USB flash drive. Make sure there are no other versions of update files present in this folder
Plug the USB flash drive into the USB port on the front of your Omnia.9sg.
Using the front panel navigation controls;
Navigate to the System menu
Then to System Configuration
Then to Software Update
Select "Update from USB"
Follow the remaining instructions on the screen
Using the NfRemote software
Select System
Then chose System Configuration
Choose Software Update
Then choose the Update Software button. In the Window that appears, browse to and select the software update file you just downloaded.
Once complete, your version will reflect the new version number 3.30.73
Updating the FPGA Firmware
After the Omnia.9sg reboots, it’s time to check and update the FPGA firmware if needed.
Navigate to System
System Configuration
Software Update.
If the FPGA version shown there is 0x90000018, it is already up to date and no further update is needed. If it is 0x90000016 or below, proceed as follows:
If there is any chance of a power outage (due to unreliable local power), this is the time to connect your Omnia.9sg to a UPS before continuing . The FPGA update takes ten minutes, and MUST NOT BE INTERRUPTED! A power failure or reboot in the middle of an FPGA update is fatal and will require a trip to a Service Center to be repaired.
After you have ensured that the unit will not suffer a power outage, click on “Update FPGA to 0x90000018.
When the FPGA update is done, disconnect the power cables, wait 30 seconds and then reconnect them.
Some units may need an Atmel update as well, depending on what software version they were running. If the "Update Atmel to 1.5" button is enabled (not grayed out) then you will want to do this update as well. This also requires a hard power-off afterward, separately from the FPGA update. It does not matter whether FPGA or Atmel is updated first. Risks here are similar to the FPGA, so take great care your unit is not rebooted during this update.
Update Notes
3.30.73
New DICE firmware version applicable from main user interface, the update can be found here.
3.30.69
RDS External Input phase issue fixed
IEEE-1588 PTP clock synchronization improved
Rewritten Livewire engine
New SNMP MIB, many issues corrected, now auto-generated
3.20.32
Dice Firmware version displayed under Hardware Info
3.20.31
RDS encoder UTF-8 translation implemented
3.20.24
MPX1/2 separate output delays added
3.20.23
RDS encoder letters É, È translation bug fixed
3.20.22
RDS encoder letter á translation bug fixed
3.20.12
Watchdog rewritten. Dice chip now hard-reset if absent or unresponsive.
Hardware device presence now probed through HAL and logged.
Several specific error messages added to replace the generic "Engine Failure".
Mainboard Reset button added to System - System Config - Power.
3.20.09
MPX input 1/2 -> MPX Output pass-through fixed (broken in 3.20.07)
3.20.08
Local input noise issue fixed
3.20.07
MPX input module moved to separate thread to stabilize CPU load
Version 3.20.04 - October 28, 2019
Clipper improvements - Cleaner Bass!
NTP now obeys user-configured server list after software restart
RDS separate injection level control for mono added
MPX2 Output Mode selection fixed
PTP two-step clock sync supported
Livewire or AES67 address display mode selectable
Primary Input silence alarm GPO option added
Audio engine hardened
Logging and diagnostics improved
Kantar version integrated 8.0
Kantar library 5.1 now resynchronizes its clock every 6 hours
SNMP PSU alarm hardware supported (for 9SG-DP units)
AF Method B bug fixed
Stream Receiver added
Dual receivers (Primary / Secondary) where Secondary can provide near seamless standby backup
Can be used as pre-clipper or local source
Silence Detect / Program Detect time now adjustable
30 Hz high pass filter added (active on Local Input only by default)
I/O loopback watchdog added.
FPGA update to 0x90000018 required for I/O loopback. This update is available from the System - System Config - Software screen.
Note, this update requires the unit be offline for fifteen minutes, and requires a hard power cycle after installation
RDS Improvements / Fixes
"Advanced RDS" Option (RDX) license added, encompassing advanced RDS functionality such as EWS/ECC, EON and the following new features:
- UECP site/encoder addresses increased to 4
- UECP multiple listening ports (4)EWS/ECC moved to Advanced/Slow Labeling. EWS/ECC Toggle switches removed, leave edit field empty to disable.
Language code added, under Advanced/Slow Labeling.
Group Sequence and Extended Group Sequence hexadecimal edit fields added.
EON reorganized, 14B burst toggle switch added.
Allow Slow Labeling Group Access toggle switch added to the UECP page, on by default. Disable to block access to
EWS/ECC/Language.
RDS PS/RT timeout now properly grayed out when UECP is enabled, active when UECP is disabled
RDS group counter added
RDS Library version 1.510 with AF Method B, multiple network lists.
RDS EON user interface parameters added (for testing purposes only)
RDS Library Version now displayed in the user interface.
RDS EWS ID now encoded correctly
RT priority now correctly handled
RDS Group 15B and Site/Encoder UECP encoding features added
RDS ECC/EWS/EON features added
RDS UECP support improved
PS/RT timeout and default fields added
RDS encoder updated, AF list stability issue corrected (no longer repeats packets),
UECP feature set extended
RDS AF list issue corrected (no longer sends invalid 0 code), RDS AF list now supports 25 frequencies