Dashboard Introduction

Prev Next

Initial Configuration

The Telos Infinity MP-16 ships from the factory unprogrammed. When first powered up from the factory, the DHCP will be enabled allowing the Panel to work in dynamic-IP mode. To put the panel into use it must be assigned a static IP address for the Primary AoIP network and the Secondary WAN network. Each panel must be programmed with the IP, Mask, and Gateway addresses and the DHCP must be disabled.

Note - Note: This next section refers to Telos Infinity Dashboard. Dashboard is the software product used to program and configure Telos Infinity systems and is available at no charge with a new system. Dashboard software updates are free as long as there is a current SLA in effect. Dashboard installation and operation is described in detail within a dedicated section later in this manual under the section “Dashboard Software”. Dashboard does not have to run for your Telos Alliance Infinity intercom to run. It is used for configuration of the intercom panels and parts of the larger Infinity system.

Configuration of hardware panel IP addresses is best achieved using the front panel “setup” menu. Once the primary IP address is installed the Dashboard software can be used to access panels. Dashbaord can be installed and run on a local PC or central server depending on the type of Infinity installation. During installation, great care must be taken to make sure each device on the network is assigned its own unique IP address and microphone Livewire+/AES67 multicast addresses.

Once the IP, Mask, and Gateway addresses have been programmed, it is possible to configure some elements of the system using the front Panel configuration tools, but it is much more convenient to provide setup using the Dashboard software.

The Dashboard software listens for Livewire+™ AES67 connected Infinity products and updates a central or local database with the appropriate configuration information.

The Telos Infinity intercom system will operate perfectly well without the Dashboard software connected. But Dashboard does provide a convenient method for configuring and testing the whole system as well as maintaining the current configuration data.

To access the webpage, enter the IP address of the computer the Dashboard software is running on with port number 5000 appended. For example, if Dashboard is running on a computer with address 192.168.0.80, then enter “http://192.168.0.89:5000” into the web browser (see Figure 1). The default user name = admin. The default password  is empty.

Figure 1 - IP address of Dashboard server entered with port 5000

In the configuration shown below in Figure 2, Dashboard is running on a laptop or PC with IP address 192.168.0.89, the same subnet as the INF-MP-16 Panels. The switch MUST be configured to support AES67 traffic! The laptop’s IP address is entered into the browser address bar with port 5000 appended to it. The browser will then display the Dashboard web page and show connected INF-MP-16’s.

Figure 2- Example configuration with Dashboard on PC

After entering the IP address and port number 5000 into the browser, the login window appears (as below). By default, “admin” is the username and password is empty.

Figure 3 - Login page

Once the Dashboard software is installed and running it automatically searches for Telos Infinity Livewire+™ AES67 connected Panels, Virtual ports, Beltpacks, and other products such as Telos Alliance xNodes and mixing consoles and will register and display them as seen in the picture below. This example system, below, shows an INF-MP-16 Panel, one INF-MP-16 with the INF-MXP-20 Expansion Panel, and two Beltpacks.

Figure 4 - Dashboard display running on a web browser

As the Telos Infinity Intercom system does not have a central matrix, there is no central storage for the configuration. Each Panel and Beltpack has a copy of the relevant parts of the configuration and it stores this in its own non-volatile memory.

In a new system Dashboard will save the configuration from each device it finds on the Livewire+™ AES67 network. As Infinity panels and beltpacks are configured in Dashboard the configuration chnages are loaded into the devices.

Each Infinity panel and beltpack has a unique identifier. If any of these devices are powered down and/or removed from the network, then when they are reconnected Dashboard will send the panel its configuration as stored in the Dashboard database. If a panel that has never been connected to the network before is added to the network, any configuration in the panel will be uploaded to Dashboard as the panel’s initial state. Using Dashboard the panel can then be reconfigured.

Getting Started

A simple configuration would consist of two Telos Infinity INF-MP-16’s and two Beltpacks with Dashboard running on a laptop, an Ethernet switch and PTP clock source. This is demonstrated in the Figure below.

Figure 5 - Simple example configuration

Note - The next section refers to Telos Infinity Dashboard. Dashboard is the software product used to program and configure Telos Infinity systems and is available from V2.0 as a free product called Dashboard Enterprise. Dashboard Enterprise is aimed at users who want regular live access to the devices but is equally suitable for users who require ad-hoc occasional use. Its operation and installation is described in detail within a dedicated section later in this manual under the section “Dashboard Software”

When first powered on the Infinity Panels and Dashboard (running on an MS Windows PC) will all advertise their availability. Dashboard will display the devices in the top left corner of the webpage as below.

Figure 6 - Example of four devices found by Dashboard

See the “Dashboard Software” section for a full description of configuring a Telos Infinity Intercom system using Dashboard. The selection boxes on the right of the Dashboard Devices window provide the following functionality.

Edit

Changes the name of the Panel, Virtual Panel, or Beltpack. In this example, the Panel names are “Director” and “Producer”, and the Beltpack names are “Floor 1” and “Floor 2”.

Manage

Launches a browser connection to the selected device. This allows configuration of the device itself. (see below). When the page launches it requests a username and password. The default username is “user” and the password is empty.

Assign

Launches a window to allow the device to be assigned to a scene or zone.

Add

Allows manual addition of a Panel, Virtual port, or Beltpack.

Sort Name

Lists the devices on Dashboard in alphabetical order.

Sort IP

Lists the devices on Dashboard in order of ascending IP address.

Sort Type

Lists the devices on Dashboard in order of type; Beltpack, Panel, or Virtual port