Performing a Factory Reset on the LA-5291, LA-5300, or UpMAX ISC via SSH
Overview
This article describes how to perform a factory reset on the following Linear Acoustic products using an SSH connection:
LA-5291
LA-5300
UpMAX ISC
The factory reset is initiated by running a reset script from the product's Linux command line.
Warning: A factory reset restores the unit to its default configuration. Back up any required settings before proceeding.
Prerequisites
Before you begin, ensure you have:
Network connectivity to the product.
The product's IP address.
A Windows PC with Tera Term installed.
Administrative access to the device.
Connect to the Product Using SSH
Open Tera Term.
Select TCP/IP.
Configure the connection using the following settings:
Setting
Value
Host
IP address of the LA-5291, LA-5300, or UpMAX ISC
Service
SSH
TCP Port
22
SSH Version
SSH2
IP Version
Auto
Select OK.
After a few seconds, a security confirmation window will appear. Select Continue.
When the SSH Authorization window opens, enter the following credentials:
Field
Value
Username
userPassword
(Leave blank)
Select OK to open the terminal session.
Perform the Factory Reset
At the command prompt, enter the following commands:
su
cd /usr/arc
./factory_reset.sh
Note: There is a space between
cdand/usr/arc.
What to Expect
After the reset script is executed:
The front panel display will go blank.
The unit will begin the factory reset process.
Once the reset is complete, the front panel display will return to normal.
The web user interface should automatically reconnect after the device finishes restarting.
Verification
After the unit has restarted:
Verify that the front panel display has returned to normal.
Connect to the web interface.
Confirm that the device has been restored to its factory default configuration.
Reconfigure the device or restore a saved configuration if required.
Troubleshooting
If the reset does not complete successfully:
Verify that the SSH connection was established using the correct IP address.
Confirm you entered the commands exactly as shown.
Ensure there is a space between
cdand/usr/arc.Allow several minutes for the reset process to complete before attempting to reconnect.
If the unit does not recover after the reset, contact Telos Alliance Technical Support for further assistance.