Important Note: This is a system-wide software update that applies major improvements to all components of the Quasar console. BOTH the Surface and the Engine must be updated at the same time. The Firmware update for all modules could be applied before or after the Surface and Engine software updates.
Components Released
Updating Software on the MTS-MON Module
Click here to download the file 1601-00577-016-quasar-mts-3.1.0-2024.12.19.itb
Connect a PC to your console network.
Open the MTS-MON Web UI at the unit's base IP address (standard HTTP port 80).
In the System menu, select Software.
Click on “Choose File,” navigate to the location where you saved the update file, and select it.
The new version will load into the currently inactive software bank and overwrite its content once you press the Upload Software button.
The page will refresh once the upload is complete, showing the new version in the unused bank.
Now select the new bank and press the “Switch to Selected Bank” button. WARNING: the console will reboot once you press the button
The system will take approx. 15 seconds to reboot, and at the end, the audio might be interrupted for about 1 second.
Updating Software on the Engine RPS Module
Click here to download the update file 1601-00607-004-quasar-gen2-mts-3.1.0-2024.12.19.itb
Connect a PC to your console network.
Open the RPS Web UI at the unit's base IP address (standard HTTP port 80).
In the System menu, select Software.
Click on “Choose File,” navigate to the location where you saved the update file, and select it.
The new version will load into the currently inactive software bank and overwrite its content once you press the Upload Software button.
The page will refresh once the upload is complete, showing the new version in the unused bank.
Now select the new bank and press the “Switch to Selected Bank” button. WARNING: The RPS Module will reboot once you press the button
The system will take approx. 15 seconds to reboot, and at the end, the audio might be interrupted for about 1 second.
Updating Software on the XR-4FAD Module
Click here to download the update file 1601-00576-008-quasar-4fa-3.1.0-2025.01.14.itb
Connect a PC to your console network.
Open the XR-4FAD Web UI at the unit's base IP address (standard HTTP port 80).
In the System menu, select Software.
Click on “Choose File,” navigate to the location where you saved the update file and select it.
The new version will load into the currently inactive software bank and overwrite its content once you press the Upload Image button.
The page will refresh once the upload is complete, showing the new version in the unused bank.
Now select the new bank and press the “Switch to Selected Bank” button. WARNING: the module will reboot once you press the button.
The system will take approx. 15 seconds to reboot, and no audio interruption will occur.
Updating Software on the MF1-ACC and MPC-ACC Modules
Click here to download the update file 1601-00592-005-quasar-acc-3.1.0-2025.01.14.itb
Connect a PC to your console network.
Open the XR-4FAD Web UI at the unit's base IP address (standard HTTP port 80).
In the System menu, select Software.
Click on “Choose File”, navigate to the location where you saved the update file, and select it.
Once you press the Upload Image button, the new version will load into the inactive software bank and overwrite its content.
The page will refresh once the upload is complete, showing the new version in the unused bank.
Now select the new bank and press the “Switch to Selected Bank” button. WARNING: the module will reboot once you press the button.
The system will take approx. 15 seconds to reboot, and no audio interruption will occur.
Updating MCU Firmware on the MTS-MON Module
Updating the MTS-MON Module to FW v4.3.0 is optional, not required, since it adds no new functionality or bug fixes to this module. You could skip this step or proceed as follows.
Click here to download the update file 1621-00180-012-quasar-mcu-4.3.0.bin
You can perform this step before or after the v3.1.0 Software update has been installed
Open the MTS Web UI at the following address: IP address/debug/mcu
The MCU Operations page will appear.
Click on “Choose File”, navigate to the location where you saved the update file, and select it. The correct MCU FW file type is .bin
Once you press the Upload MCU Firmware button, the new version will load into the firmware bank and overwrite its content.
The page will refresh once the upload completes, showing the “No file chosen” message.
From the main menu, select the Module Information link. The following page will appear:
Please double-check that the new Firmware version is correctly reported as 4.30 hw0.
Note - A Firmware update does not cause any audio interruption.
Updating MCU Firmware on the XR-4FAD Module
Updating the XR-4FAD Module to FW v4.3.0 is required for adding the new Bargraph Dimming functionality.
Click here to download the update file 1621-00180-012-quasar-mcu-4.3.0.bin
You can perform this step before or after the v3.1.0 Software update has been installed
Open the XR-4FAD Web UI at the following address: IP address/debug/mcu
The MCU Operations page will appear.
Click on “Choose File”, navigate to the location where you saved the update file, and select it. The correct MCU FW file type is .bin
Once you press the Upload MCU Firmware button, the new version will load into the firmware bank and overwrite its content.
The page will refresh once the upload completes, showing the “No file chosen” message.
From the main menu, select the Module Information link. The following page will appear:
Please double-check that the new Firmware version is correctly reported as 4.30 hw0.
Note - A Firmware update does not cause any audio interruption.
Updating MCU Firmware on the MF1-ACC and MPC-ACC Modules
Updating the Accessory Modules to FW v4.3.0 is optional, not required, since it adds no new functionality or bug fixes to these modules. You could skip this step or proceed as follows:
Click here to download the update file 1621-00180-012-quasar-mcu-4.3.0.bin
You can perform this step before or after the v3.1.0 Software update has been installed
Open the XR-4FAD Web UI at the following address: IP address/debug/mcu
The MCU Operations page will appear.
Click on “Choose File,” navigate to the location where you saved the updated file, and select it. The correct MCU FW file type is .bin
Once you press the Upload MCU Firmware button, the new version will load into the firmware bank and overwrite its content.
The page will refresh once the upload completes, showing the “No file chosen” message.
From the main menu, select the Module Information link. The following page will appear:
Please double-check that the new Firmware version is correctly reported as 4.30 hw0.
Updating MCU Firmware on the SR-4FAD Module
There is no Firmware update for the SR Modules.
Updating Firmware on the SmartKey Modules
Click here to download the update file 1601-00627-001+KT028-00-0_FW_V1.1.5.9.sys
You can perform this step before or after the v3.1.0 Software update has been installed.
Navigate to the SmartKeys page of the MTS-MON Web UI
The SmartKey Module Setup page will appear.
Click on “Choose File”, navigate to the location where you saved the update file, and select it. The correct SmartKey FW file type is .sys
Press the Update Firmware button. Once the page refreshes, hit F5 on your keyboard to refresh the browser tab and check that all connected Button Modules have been updated to the new version.
Updating the Quasar Engine
Click here to download upate file 1601-00579-013-QuasarEngine-3.1.2-SM-update.tar
Connect a PC to your console network.
Open the Quasar Engine Web UI at the unit's base IP address (standard HTTP port 80).
In the System menu, select Software.
If both of the Engine’s software banks are used, and the “Choose File” option is not displayed here, select the bank currently in use and click the Commit button. Otherwise, skip this step.
Click on “Choose File”, navigate to the location where you saved the update file, and select it.
Wait until the software package appears in the field next to the button.
Click on the Upload button. A message will appear to inform you that the file is being uploaded. Once complete, you will receive a confirmation message. Refresh the page.
Select the new software bank by clicking on the radio button
Click the Apply Selected Bank button.
A dialog will appear asking for confirmation, and the system will be restarted.
Warning – When the Engine will reboots after selecting a new software bank, connections to the surface will be reset, and audio will be interrupted for more than one minute
Release notes
Software release notes for all versions are moved to their own document. Click here for that document.
Let us know how we can help
If you have further questions on this topic or have ideas about improving this document please contact us.